Chapter 4 Maintenance

   

 

59 

 

Chapter 4   Maintenance 

 

 
 

4.1 Cleaning 

 

 
 

This system is hardly needed maintenance daily. However, to keep the system clean, clean it up 
regularly. 

 

 
 
 

 

Do not attempt inspections or repairs on the internal part of the equipment by 
yourself. Inspections or repairs by non-qualified maintainers may cause a fire or 
electric shock. Ask for internal inspections or repairs of the equipment to the sales 
department of JRC, a nearby branch office, business office, or any agents of JRC. 

 

 
 
 

 

When cleaning the system surface, remove dust and garbage and wipe with a 
cottony cloth. Do not use solid materials such as screwdriver and sandpaper.   

Otherwise, it may cause damage on the paint or seal on the surface. 

 

CAUTION 

WARNING 

Содержание JCX-161

Страница 1: ...m System Watch Alarm System ISO 9001 ISO 14001 Certified FEB 2017 Edition 2 CODE No 7ZPNA4317A Not use the asbestos For further information contact URL Head office http www jrc co jp eng Marine Servic...

Страница 2: ......

Страница 3: ...officer cannot fulfill his duties for any reason the system alerts the captain or other qualified personnel This system conforms to the performance standards of the IMO resolution MSC 128 75 and IEC...

Страница 4: ...marks indicate CAUTION including DANGER and WARNING Detailed contents of CAUTION Electric Shock in the example on left are shown in the mark Disassembly Prohibited marks indicate prohibition Detailed...

Страница 5: ...ch office business office or any JRC agents Continued use of water damaged equipment may result in a fire electrical shock or equipment malfunction Do not attempt inspections or repairs on internal pa...

Страница 6: ...ectrical shock Do not allow any loose wires or metal objects to fall inside of equipment This may result in a fire electrical shock or equipment malfunction Do not install the system near to a water s...

Страница 7: ...re or earth leakage Avoid sharing a power source with a system that generates a large amount of electronic noise such as an air conditioner The system may not function properly because of short time v...

Страница 8: ...in make sure that the screen of the LCD display unit goes out If the power switch is turned on immediately after turning off the equipment may be cause of malfunction Do not touch the system if your h...

Страница 9: ...Equipment Appearance vii JCX 161 Bridge Navigational Watch Alarm System External Appearance...

Страница 10: ...Reset button unit NCJ 895 8 1 4 5 Motion sensor NYG 5 Option 9 1 4 6 LED Warning lamp unit NCD 2257 Option 10 1 4 7 Reset button unit Waterproof NCJ 896 Option 11 1 5 System diagram 12 Chapter 2 Name...

Страница 11: ...sound 44 3 4 7 Changing password 45 3 5 Backup officer setting 46 3 5 1 Setting backup officer 46 3 6 Alarm transfer from other navigational equipment 47 3 6 1 Outline 47 3 6 2 Stopping ACK operation...

Страница 12: ...7 7 1 Disposal of the system 67 7 2 Chinese version of RoHS 67 Chapter 8 Specification 69 8 1 Control unit NCK 175 69 8 2 LCD display unit NWZ 4650 70 8 3 Buzzer unit NVS 785 70 8 4 Reset button unit...

Страница 13: ...n is performed within the dormant period the system recognizes that the duty officer cannot fulfill his duties and outputs an alarm in the bridge If no response is given even after that it alerts the...

Страница 14: ...e the visual indication is initiated the BNWAS additionally sounds a 1st stage bridge audible alarm on the bridge 3 Second Stage Remote audible alarm 2nd Stage Remote audible alarm If not reset within...

Страница 15: ...e reset within 15 s in anywhere since the visual indication starts The reset function is equipped also in the LCD display unit NWZ 4650 2 Motion sensor type reset device option The motion sensor NYG 5...

Страница 16: ...rd 7ZPNA4319 power cable CFQ 5766B data cable CFQ 5951B Fuse 2A 1A 1 piece each 3 Buzzer unit NVS 785 8 0 2 4 Reset button unit NCJ 895 3 0 2 Option 5 Motion sensor NYG 5 1 0 4 6 LED warning lamp unit...

Страница 17: ...ter 1 General Outline of Equipment 5 1 4 Outline dimensions 1 4 1 Control unit NCK 175 Control unit NCK 175 Outline Dimensions COLOR N4 SEMI GLOSS MASS APPROX 4 5kg IP SPEC IP22 UNIT mm CATEGORY Prote...

Страница 18: ...eral Outline of Equipment 6 1 4 2 LCD display unit NWZ 4650 LCD display unit NWZ 4650 Outline Dimensions attached self supported stand COLOR N4 SEMI GLOSS MASS APPROX 0 6kg IP SPEC IP22 UNIT mm CATEGO...

Страница 19: ...Chapter 1 General Outline of Equipment 7 1 4 3 Buzzer unit NVS 785 Buzzer unit NVS 785 Outline Dimensions COLOR N4 SEMI GLOSS MASS APPROX 0 2 kg IP SPEC IP22 UNIT mm CATEGORY Protected...

Страница 20: ...Chapter 1 General Outline of Equipment 8 1 4 4 Reset button unit NCJ 895 Reset button unit NCJ 895 Outline Dimensions COLOR N4 SEMI GLOSS MASS APPROX 0 2 kg IP SPEC IP22 UNIT mm CATEGORY Protected...

Страница 21: ...Chapter 1 General Outline of Equipment 9 1 4 5 Motion sensor NYG 5 Option Motion sensor NYG 5 Outline Dimensions COLOR N4 SEMI GLOSS MASS APPROX 0 4 kg IP SPEC IP22 UNIT mm CATEGORY Protected...

Страница 22: ...1 General Outline of Equipment 10 1 4 6 LED Warning lamp unit NCD 2257 Option LED warning lamp unit NCD 2257 Outline Dimensions COLOR N4 SEMI GLOSS MASS APPROX 0 2 kg IP SPEC IP22 UNIT mm CATEGORY Pr...

Страница 23: ...neral Outline of Equipment 11 1 4 7 Reset button unit Waterproof NCJ 896 Option Reset button unit Waterproof NCJ 896 Outline Dimensions COLOR N4 SEMI GLOSS MASS APPROX 0 5 kg IP SPEC IP56 UNIT mm CATE...

Страница 24: ...Chapter 1 General Outline of Equipment 12 1 5 System diagram...

Страница 25: ...175 to each unit of the system and there is no power source switch at any devices The power switch of the control unit is located in the chassis and using the high voltage supply which is danger Pleas...

Страница 26: ...Chapter 2 Names and Functions of System Components 14 2 How to turn on the power In order to switch on the power turn the AC switch and DC switch on DC ON AC ON DC OFF AC OFF...

Страница 27: ...Chapter 2 Names and Functions of System Components 15 3 How to turn off the power DC ON AC ON DC OFF AC OFF In order to turn off the power turn the AC switch and DC switch off...

Страница 28: ...rated variously with 9 buttons under the Liquid Crystal Display LCD 2 2 1 Mark and function of button No Mark of button Function of button 1 Contrast is adjusted 2 Brightness is adjusted 3 The menu mo...

Страница 29: ...s 17 No Mark of button Function of button 7 Selections or settings are decided 8 Sound of audible alarm units occurring system abnormality and bridge alarm is deactivated 9 An emergency call is genera...

Страница 30: ...per part 3 MODE The current operation mode is displayed When the power is turned on it starts in MANUAL ON mode 4 BACKUP OFFICER The selected back up officer is displayed with as mark A back up office...

Страница 31: ...s up alternately with ORANGE and WHITE 1 Display at visible indication VISUAL INDICATION for meaning visual indication is displayed in and remaining time is displayed at until the next alarm stage 2 D...

Страница 32: ...ible alarm 2ND STAGE REMOTE ALARM for meaning the 2nd Stage Remote audible alarm is displayed in and remaining time is displayed at until the next alarm stage 4 Display at Third Stage Remote audible a...

Страница 33: ...remote audible alarm LED lamp This is illuminated when the 1st Stage Bridge audible alarm 2nd stage remote audible alarm and 3rd stage remote audible alarm is output It remains off in normal state The...

Страница 34: ...and functions of system components No Name Function Buzzer Audible alarm device This is sounded at the first stage audible alarm or the various alarms Reset button switch This resets the dormant peri...

Страница 35: ...king Sound Illuminated The blink patterns change with alarm stages Blink pattern at visual indication 1 s turn on 1 s turn off Turn on Turn off 1 sec 1 sec Blink pattern at first stage bridge audible...

Страница 36: ...mes and Functions of System Components 24 1 sec 1 sec 200ms 200ms 200ms 200ms 200ms 200ms 200ms Turn on Turn on Turn on Turn on Turn on Turn on Turn on 200ms 200ms 200ms 200ms 200ms 200ms Off Off Off...

Страница 37: ...ted from the human body and resets the dormant period automatically 2 5 1 Names and functions of system components No Name Function Sensor This is the sensing element Do not cover this area 1 Alarms t...

Страница 38: ...9 HUMAN 2 Specification of a motion sensor As below the human body is detected in the range of vertical angle 81 to horizontal angle 100 and an automatic reset is made when a person crosses moves in...

Страница 39: ...change place Also do not close the following heat radiating things to NYG 5 a Sunlight or another light strikes the NYG 5 directly b Its installed place is above a heating appliance such as a stove or...

Страница 40: ...urs DIMMER Button This is the dimmer adjust switch of the LED When the button is pressed brightness is changed to bright medium dark bright in the 3 steps The LED lamp can be turned on with operating...

Страница 41: ...turn off 200ms 200ms Turn on Turn on 1 sec 1 sec Turn off Blink pattern at second stage remote audible alarm 2 times blink 1 s 1 s turn off 200ms 200ms 200ms 200ms Turn on Turn on Turn on Turn on 200...

Страница 42: ...he following four functions 1 Report an end of the dormant period as a visual indication devise 2 Sound 1st stage bridge audible alarm 3 Reset dormant periods as a reset device 4 Stop visual indicatio...

Страница 43: ...the visual indication and the audible alarm The LEDs around the reset button switch is illuminating in normal state and blinks after activated visual indication DIMMER Button This is the brightness co...

Страница 44: ...urn off Turn on Turn off 1 sec 1 sec Blink pattern at first stage bridge audible alarm 1 time blink 1 s 1 s turn off 200ms 200ms Turn on Turn on 1 sec 1 sec Turn off Blink pattern at second stage remo...

Страница 45: ...ALARM operation 34 3 2 Operation mode change 36 3 3 Resetting dormant period 38 3 4 Time setting 39 3 5 Backup officer setting 46 3 6 Alarm transfer from other navigational equipment 47 3 7 Emergency...

Страница 46: ...manner 2 First Stage Bridge audible alarm 1st Stage Bridge audible alarm If not reset within 15 seconds since the visual indication is initiated the BNWAS additionally sounds a 1st stage bridge audibl...

Страница 47: ...dge LCD display unit NWZ 4650 Illuminated Blinking Blinking Blinking Blinking Bridge LED warning lamp unit NCD 2257 Blinking Blinking Blinking Blinking Bridge Reset button unit NCJ 895 896 Illuminated...

Страница 48: ...the menu mode is displayed 2 Select SET VALUE and then press Press Since it become a password input state input your 4 digit password and then press When your password is correct the next menu screen...

Страница 49: ...our required operation mode with and then press Then the selected operation mode is turned to ON When this setting change is canceled press Multiple modes cannot be selected to ON 5 When press It retu...

Страница 50: ...hods are available 1 Using push button Press any button of LCD display unit NWZ 4650 or press a reset button switch of the reset button units NCJ 895 or the reset button unit Waterproof NCJ 896 2 Auto...

Страница 51: ...g This system can change the following the time settings Setting of the dormant period From 3 minutes to 12 minutes Third stage remote audible alarm transfer delay time Alarm transfer delay time betwe...

Страница 52: ...d again 0000 as the default password is set 3 4 2 Changing dormant period setting 1 Call the SET VALUE screen in according to the procedure of the section 3 4 1 Call of menu mode screen 2 Select ALARM...

Страница 53: ...TAGE with and then press 4 Change the 3rd stage remote audible alarm transfer delay time Select your required transfer delay time with and then press When this setting change is canceled press A trans...

Страница 54: ...een in according to the procedure of the section 3 4 1 Call of menu mode screen 2 Select ALARM TIME and then press ALARM TIME screen is displayed 3 Select BRIDGE with and then press 4 Change the bridg...

Страница 55: ...and then press OFFICER NAME screen is displayed 3 Select an officer name for edit and the press The officer name edit screen is displayed 4 Select one desirable character with and then press C deletes...

Страница 56: ...mode screen 2 Select BUZZER SOUND and then press BUZZER SOUND screen is displayed 3 Select CONTINOUS and then press 4 Select the continuous sound or intermittent sound Select ON or OFF with and then p...

Страница 57: ...E screen in according to the procedure of the section 3 4 1 Call of menu mode screen 2 Select PASSWORD and then press PASSWORD screen is displayed 3 Input the new password Press and then input the new...

Страница 58: ...FICER and then press 3 Select the backup officer Since BACKUP OFFICER screen is displayed select the changing officer with and then press 4 Select ON or OFF Select ON or OFF with and then press When t...

Страница 59: ...a 2nd and a 3rd stage remote audible alarms 5 When the buzzer sound stopping operation is performed by the BNWAS the sound of the BNWAS is stopped Select ALARM BRIDGE ALARM from MENU alarm contents a...

Страница 60: ...m MENU and press alarm contents are displayed in the screen confirm its contents When alarms are registered they are displayed on two or more pages therefore press in order to change the pages 2 Selec...

Страница 61: ...EA sentences It conforms to IEC61162 1 ALR sentences ALR hhmmss ss xxx A A c c hh CR LF Time of alarm condition change UTC Alarm s description text Alarm s acknowledge state A acknowledged V unacknowl...

Страница 62: ...remote audible alarms are generated 4 Until the alarm transfer delay time is passed second stage remote audible alarms are continued 5 When the alarm transfer delay time is passed third stage remote a...

Страница 63: ...At an emergency call all audible alarm devices buzzers are sounded 1 Execution of EMERGENCY CALL Press of LCD display unit NWZ 4650 for 2 seconds or more Or press the button for 2 seconds or more whi...

Страница 64: ...alarm It does not transfer to the 3rd stage remote audible alarm 1 Execution of OFFICER CALL Press on the LCD display unit NWZ 4650 Select OFFICER CALL and then press Since pop up of OFFICER CALL OK i...

Страница 65: ...l of alarm If any problem occurs with the system the LCD screen on the LCD display unit NWZ 4650 is displayed the following contents and AL icon of the bottom in the screen blinks An alarm buzzer from...

Страница 66: ...unit NCK 175 COMM ERROR is displayed Also when HBT communication error is detected between LCD display unit and BAM or other navigational unit COMM ERROR is displayed 4 When an abnormality of the sys...

Страница 67: ...finished press and then it returns to the countdown screen 3 10 Display of alarm history A maximum of six alarms can be stored in the alarm history list which is displayed at the alarm history screen...

Страница 68: ...normal or not 1 Press 2 Select BUZZER TEST and then press 3 Select a channel required test confirmation and then press 4 Select ON or OFF with and then press 5 When set to ON the selected channel s bu...

Страница 69: ...contrast can be adjusted in incremental steps with pressing 3 12 2 Setting of brightness Brightness of the LCD screen can be changed in maximum middle minimum of the three steps with pressing dimmer...

Страница 70: ...th the following operation 1 Press 2 Select DISPLAY and then press 3 Select BACK LIGHT and then press 4 Select ORANGE or WHITE with and then press 3 12 5 Default setting value Default setting values o...

Страница 71: ...ions or repairs by non qualified maintainers may cause a fire or electric shock Ask for internal inspections or repairs of the equipment to the sales department of JRC a nearby branch office business...

Страница 72: ...Confirmation of the visual indication function Set the operation mode into MANUAL ON and then set the dormant period INTERVAL into 3 minutes After 3 minutes confirm the visual indication start at the...

Страница 73: ...ed Adjust the dimmer P57 NYG 5 reset does not work There are air conditioning devices around NYG 5 Take apart the air conditioning devices from NYG 5 P26 Visual indication does not work at NCJ 895 896...

Страница 74: ...set button unit Waterproof Membrane switch replacement kit H 7ZZNA4112 7ZZNA4112 4 5 Periodic replacement part Since the following table s parts in this system have lifetime the parts are needed perio...

Страница 75: ...d to direct sunshine inner parts of it get an indiscernible increase in temperature Do not put it in direct sunshine The reset button unit Waterproof NCJ 896 is IP56 the other units are IP22 Please us...

Страница 76: ...Chapter 5 Usage Environment 64...

Страница 77: ...the system is out of warranty the service is available for a fee upon request Please contact to the vender the sales department of JRC a nearby branch office business office or any agents of JRC Let...

Страница 78: ...r sounds Yes No 2 AC FAIL is displayed on NWZ 4650 and the buzzer sounds Yes No 3 COMM ERROR is displayed on NWZ 4650 and the buzzer sounds Yes No 4 In the operation mode a countdown timer does not co...

Страница 79: ...der a nearby branch office or local government 7 2 Chinese version of RoHS Type JCX 161 Name Bridge Navigational Watch Alarm System Pb Hg Cd Cr6 PBB PBDE Control Unit LCD LCD Display Unit Audible Alar...

Страница 80: ...Chapter 7 Disposal 68...

Страница 81: ...ing temperature range 15 C to 55 C 7 Protection class IP22 8 Signal input for reset buttons 6 ports 9 External Navigational equipment reset contact input 2 ports 10 Motion sensor input 2 ports 5 signa...

Страница 82: ...rature Operating temperature range 15 C to 55 C 7 Protection class IP22 8 Category Protected 9 Compass safe distance 0 3m Standard Compass 0 2m Steering Compass 8 3 Buzzer unit NVS 785 1 Power supply...

Страница 83: ...s IP22 8 Category Protected 9 Compass safe distance 0 1m Standard Compass 0 1m Steering Compass 8 5 Motion sensor NYG 5 1 Power supply rating 12 V DC 30 10 2 Power consumption 0 4W max 3 Dimensions Ap...

Страница 84: ...P22 8 Category Protected 9 Compass safe distance 0 1m Standard Compass 0 1m Steering Compass 8 7 Reset button unit Waterproof NCJ 896 1 Power supply rating 12 V DC 30 10 2 Power consumption 0 6W max 3...

Страница 85: ......