Chapter 2 Names and Functions of System Components
23
1
)
Visual indication function of reset button unit
Normal
state
Visual
Indication
1st stage
Bridge
audible
alarm
2nd stage
remote
audible
alarm
3rd stage
remote
audible
alarm
EMERGENCY
CALL
Bridge
Alarm
BAM
EMERGENCY
CALL
Illuminated
Blinking
Blinking
Blinking
Blinking
Blinking
Blinking
Sound/
Illuminated
The blink patterns change with alarm stages.
Blink pattern at visual indication
1 s turn on
-
1 s turn off
Turn on
Turn off
1(sec)
1(sec)
Blink pattern at first stage bridge audible alarm
1 time blink
/
1 s
-
1 s turn off
200ms
200ms
Turn on
Turn on
1(sec)
1(sec)
Turn off
Blink pattern at second stage remote audible alarm
2 times blink
/
1 s
-
1 s turn off
200ms
200ms
200ms
200ms
Turn on
Turn on
Turn on
Turn on
200ms
Off
Turn off
1(sec)
1(sec)
Blink patterns at third remote audible alarm
200 ms turn on
-
200 ms turn off repeat