Chapter 3 Operation
39
as before version software.
The input NMEA sentences correspond with the EVE sentences.
The tag code has to be set as "BNWAS", and the event description part has to be set as
"Operator activity".
Sample:
$XXEVE,,BNWAS,Operator activity*hh<CR><LF>
3.4 Time setting
This system can change the following the time settings.
Setting of the dormant period
From 3 minutes to 12 minutes
Third stage remote audible alarm transfer delay time
Alarm transfer delay time between 2nd stage remote audible alarm and 3rd stage
remote audible alarm
0 second, or a desired value from 90 seconds to 180 seconds
Bridge alarm transfer delay time
From 0 to 30 seconds
3.4.1 Call of menu mode screen
1) Press .
2) Select [SET VALUE], and then press .
3) Password Input