NXU-2B Operations Manual
4-3
Interoperability Now!
Note: If data is to be transferred across the IP link, the NXU-2B serial port must not
be in the Command Mode (see Section 3.4.1). Be sure to return the unit to the
Transparent Mode (by issuing a TRAN command) if you have placed the unit in
Command Mode.
4.4.5
Auxiliary I/O
The NXU-2B has two sets of independent inputs and outputs that may be used for control of the
user’s equipment. AUX IN 0 and AUX IN 1 are active-low inputs which, when activated on one
end, will cause AUX OUT 0 and AUX OUT 1 on the other end to become active. The AUX OUT
lines are open drain devices, and each is capable of sinking 100 mA.
Note: These auxiliary I/O
lines are designed for switching and control applications, and do not have quick enough response
times to send or receive data.
4.5
Controlling Connections
Normally the NXU-2B client automatically connects to the preprogrammed NXU-2B server
when power is applied. The user may also manually control the connection state of the NXU-2B
client. This can be done via the serial port (by entering command mode as described in Section
3.4.1) or via the network using Telnet or a Web Browser.
4.5.1
Web Browser Control
The NXU-2B client connection may be managed by browsing to the NXU-2B client IP address
and selecting the Connection Management menu option. The user may then issue connect or
disconnect commands via the web browser.
Figure 4-1 NXU-2B Connection Management Screen
Содержание NXU-2B
Страница 8: ...NXU 2B Operations Manual viii blank page...
Страница 18: ...NXU 2B Operations Manual 1 10 End of Section One...
Страница 28: ...NXU 2B Operations Manual 2 10 End of Section Two...
Страница 60: ...NXU 2B Operations Manual 6 8 End of Section Six...
Страница 62: ...NXU 2B Operations Manual 7 2 End of Section Seven...
Страница 68: ...NXU 2B Operations Manual 8 6 End of Section Eight...