Fixed Network

Installation Manual

GXY-UM-00760-EN-FCC (February 24, 2014 11:13 AM) 

Summary of Contents for GALAXY II

Page 1: ...need new picture GALAXY II Gateway Receiver Fixed Network Installation Manual GXY UM 00760 EN FCC February 24 2014 11 13 AM...

Page 2: ...GALAXY II Gateway Receiver Page ii February 2014...

Page 3: ...ndard Components 9 Tools and Materials customer supplied 10 Using the V block Clamps 10 Banding Mounting 12 ELECTRICAL CONNECTIONS 14 AC Power 14 M12 Connector Assembly 14 ELECTRICAL NETWORK INSTALLAT...

Page 4: ...GALAXY II Gateway Receiver Page iv February 2014...

Page 5: ...xposure in excess of limits for general population uncontrolled exposure a 20 centimeter distance between the transmitter and the body of the user must be maintained during testing No FCC license is r...

Page 6: ...diameter pole mount Aluminum V blocks 2 5 24 outside diameter pole mount BAND IT mounting bands Size Height 21 includes antennas Width 36 Depth 6 Weight 11 5 lb Enclosure Sealed metallized fiberglass...

Page 7: ...ble and power supply If your existing gateway has a gray power cable and 12V power supply Figure 1 replace them with the 24V power supply Figure 2 which is included in the GALAXY II gateway packaging...

Page 8: ...g the network gateway receiver For optimal reception and transmission locate the network gateway transceiver and antennas in line of sight view of the desired endpoints Avoid installing the gateway ne...

Page 9: ...ate and antennas V block clamps or banding and locking equipment for attaching a gateway receiver to a pole 100 foot or 300 foot power cable M12 connector AC to DC power supply and power cord Figure 4...

Page 10: ...anding Mounting on page 12 1 Open the bag of mounting equipment 2 Place two bolts 3 8 16 x 5 inches through the holes in the top of the gateway mounting backplate Figure 5 Use the side holes for horiz...

Page 11: ...e gateway is sufficiently secured to the pole 8 Repeat Steps 6 and 7 for attaching the V block clamp mounting bracket hardware to the bottom bolts of the gateway mounting backplate Side View Back Side...

Page 12: ...Instructions P05886 pdf for more information This is especially applicable when mounting on a non tapered vertical pole as the banding could loosen over time resulting in the unit sliding down the pol...

Page 13: ...tions enclosed with the BAND IT tool for attaching the network gateway receiver to a pole 3 Using a 1 2 inch wrench the recommended torque for the 5 16 24 screw that attaches the gateway bracket to th...

Page 14: ...power cable 100 feet or 300 feet with 308 in line connector end 308 in line connector anti tamper collar Outdoor rated Cat5e Ethernet cable LAN gateways only customer supplied Coax stripper customer...

Page 15: ...each screw after the wire has been connected Function Wire Female insert connector Female Insert Diagram Top View Female Insert Photo Top View RS232 White 4 V DC Drain 8 center V DC Black 3 V DC Blue...

Page 16: ...to the 308 connector of the AC to DC power supply and snap the anti tamper collar over the connection 11 Connect the power cord to the power supply and then plug the three prong male end of the power...

Page 17: ...power supply and outlet in environmentally controlled indoor locations Use of a NEMA 4 Enclosure AC to DC power supply used outdoors or in a non environmentally controlled indoor location requires a c...

Page 18: ...In line Connector End and Power Cord supplied 120VAC Grounded Outlet customer supplied To Utility Network Outdoor rated CAT5e Ethernet Cable customer supplied LAN RJ45 Ethernet Connection customer sup...

Page 19: ...ngth up to 300 feet long 66233 013 When connecting directly to batteries as in the case of a solar assembly the electrical requirement is 300 mA minimum 12V DC However when using 12V DC the maximum le...

Page 20: ...er External DC Power Source Connections Wire Color for 66233 020 External DC Power Source Drain no insulation Negative Black Negative Brown Not needed cut off Red Positive Light Blue Not needed cut of...

Page 21: ...tomer supplied Metallic Housing Insulator Insert Halves Cable Gland Figure 22 RJ45 plug components 1 Feed the cord set cable through the dome nut end of the cable gland 2 Push down the RJ45 plug latch...

Page 22: ...nut to 30 45 inch pounds using wrenches 6 Tighten the dome nut to 20 inch pounds using a wrench The dome nut seal must be in firm contact with outdoor rated Cat 5e Ethernet cable 7 Remove the bayonet...