background image

44

5.1. No special conditions are required for the 

procedure

 

The  room  should  be  dry  and  warm.  During  the 
procedure  the  patient  should  be  positioned 
comfortably, seated or lying. After the procedure 
it is recommended to remain relaxed for 10 – 15 
minutes.
Products  recommended  for  use  with  DiaDENS-
Cosmo:
— DiaDENS-Cosmo series facial beauty masks;
—  tissue  mask  to  be  used  with  physiological 

solution (0,9 % NaCl solution) or 1 % Karlsbad 
salt solution 

5.2. Beauty mask allergenicity test 

All  DiaDENS-Cosmo  series  facial  beauty  masks 
are  hypoallergenic.  However  if  you  are  prone  to 
allergic reactions:
1) apply a drop of the cosmetic solution on a small 

skin area close to the elbow and let it dry; 

2) if skin redness is evident in the area where the 

drop was applied within 1–2 hours, do not use 
this beauty mask for treatment. 

5.3. Skin preparation for treatment

 

Make  sure  that  before  the  procedure  you 
take  off  all  metal  hairpins  or  decorations 
that were on your head. 
Do not use the unit if you have conductive 
jewelry  on  as  it  may  significantly  decrease 
effect of the procedure. 
Do not apply the unit to damaged skin or to 
the skin showing signs of inflammation on 
the face or around  it. 

 

It  is  very  important  for  your  safety  that  during 
treatment  your  facial  skin  should  be  free  from 
makeup. 
The following steps should be taken:
1) remove all makeup from your face, using tonic;
2) wash your face thoroughly with a large quantity 

of running water;

appliCatioN  iNStruCtioNS 

5

Содержание DiaDENS Cosmo

Страница 1: ...30 DiaDENS Cosmo FOR Contact support jpastar com 888 www jpastar com 709 9457 JPA INFORMATION MORE Instrument Cosmetology In Home The Manual Operations...

Страница 2: ...RC ART LLC Skin Care Unit DiaDENS Cosmo Operating Manual RC ART 14 0 03 71 03 RE Russia EU all USA Canada...

Страница 3: ...5 Operating instructions 44 6 Box contents 50 7 Maintenance and battery replacement 51 8 Troubleshooting 52 9 Technical information 53 10 Manufacturer s warranties 56 11 Manufacturer s address 57 12...

Страница 4: ...33 To ensure effective and safe usage of the unit please read carefully all sections of this manual Thank you for purchasing the DiaDENS Cosmo unit...

Страница 5: ...the information marked with this sign This information is important for ensuring safe and effective use of the unit The information contained in this Operating Manual is important for your safety and...

Страница 6: ...ion regulations Operating conditions temperature 10 to 35 0 relative air humidity 30 to 93 atmospheric pressure 70 to 106 kPa 525 to 795 mm Hg Warning If the unit was stored at the ambient temperature...

Страница 7: ...e of which may restrict or preclude from the application of the unit for medical reasons They include an implanted heart pacesetter or other implanted electronic devices idiosyncrasy to electric curre...

Страница 8: ...and therefore skin nutrition It becomes dry and less elastic changes its colour and becomes wrinkled While we cannot stop the pace of time modern cosmetology provides every opportunity to protect our...

Страница 9: ...ed use of the device 3 The DiaDENS Cosmo unit is designed for cosmetological treatment of the facial skin The treatment does not require any special conditions The unit can be used at home or at beaut...

Страница 10: ...39 unit description 4 Picture 1 Arrangement of the unit Front...

Страница 11: ...40 Picture 2 Arrangement of the unit Back with the conducting cuff conducting layer...

Страница 12: ...41 Cable input Unit with the cable connected Picture 3 Arrangement of the unit Cable input and unit with the cable connected Picture 4 Arrangement of the unit Battery compartment Battery compartment...

Страница 13: ...electrode connected Do not connect any detachable electrodes other than the mask electrode designed for use with DiaDENS Cosmo Picture 5 Mask electrode Do not connect the mask electrode to any type o...

Страница 14: ...eyboard Treatment power step up Unit on off Operation mode change Nourishment Lymph drainage Start Pause starts and stops operation in the selected mode Treatment power step down Liquid crystal displa...

Страница 15: ...n a small skin area close to the elbow and let it dry 2 if skin redness is evident in the area where the drop was applied within 1 2 hours do not use this beauty mask for treatment 5 3 Skin preparatio...

Страница 16: ...es in the human body an insignificant number of people maximum 2 3 show insufficient response or complete lack of response to the treatment without any negative consequences Depending on your skin typ...

Страница 17: ...e that there are no impact marks on its case and the liquid crystal display of the unit is not damaged Make sure that there are no traces of foreign materials or signs of damage on the cuff electrode...

Страница 18: ...the beauty mask with any solution not recommended for use with DiaDENS Cosmo Warning Do not use any masks other than those recommended for use with the unit Other masks were not tested for compatibili...

Страница 19: ...erent electric stimulation sensitivity and some people may not feel anything at the maximum power This is not a defect of the unit and does not decrease effect of the procedure If you have any unpleas...

Страница 20: ...Store the mask electrode dry Make sure that the cosmetic solution does not dry on the mask electrode Clean the mask electrode immediately after each procedure Do not continue using the mask electrode...

Страница 21: ...ing and cleaning DiaDENS Cosmo beauty mask 6 Cuff extender 1 Operating manual 1 Battery 2 Consumer package 1 The box may additionally contain test samples of other beauty mask tested by the manufactur...

Страница 22: ...eral patients Use soap and running water for cleaning 7 2 If the unit will not be used for a long period of time more than 3 days remove the batteries from the battery compartment This will prevent th...

Страница 23: ...nds an alarm and switches off automatically contact a representative of the company see Section 11 The unit does not start treatment no skin contact symbol 1 Make sure that the cuff electrode is in ti...

Страница 24: ...for more than 3 min 9 5 Stimulation impulse frequency in the Nourishment mode 100 30 Hz 9 6 Stimulation impulse frequency in the Lymph mode 100 30 Hz and 50 15 Hz 9 7 Treatment duration 15 1 min 9 8 R...

Страница 25: ...54 200 Ohm 0 5 V 20 2 5 V 20 500 Ohm 0 77 V 20 Epulse 0 92 uJ 4 V 20 Epulse 25 uJ 1 kOhm 0 9 V 20 4 7 V 20...

Страница 26: ...55 2 kOhm 1 1 V 20 5 3 V 20 9 9 Effective current Ieff for load resistance 500 Ohm Mode Power level Min Power level Full Lymph drainage Ieff 0 43 mA Ieff 2 22 mA...

Страница 27: ...it shall not be liable for defects if they have occurred after the transfer of the unit to the user due to 1 failure of the user to observe the transportation storage maintenance and operation rules...

Страница 28: ...57 manufacturer s address 11 RC ART LLC Academika Postovskogo St 15 Ekaterinburg 620146 Russia Tel 7 343 267 23 30 http www denascorp ru e mail corp denascorp ru...

Страница 29: ...any questions regarding the operation of the unit purchase of the consumables etc you may contact Distributor contacts 12 Full name Telephone Website www denascorp ru Telephone 8 800 200 1919 free ca...

Страница 30: ...OOO RC ART Ger t zur kosmetologischen Behandlung DiaDENS Cosmo Bedienungsanleitung RC ART 14 0 03 71 03 RE Russia EU all USA Canada...

Отзывы: