4
www.jperkinsdistribution.co.uk
Data StOrE/LOaD
Five batteries’ data can be stored per charger (20 in total on the LiPro Quad 6). This means you can
store settings for particular batteries charge and discharge often. This data can be loaded at any
time to avoid the need to set program settings every time.
CyCLIC ChargIng/DISChargIng
1 to 5 cyclic and continuous process of charge>discharge or discharge>charge is operable for
battery refreshing and balancing to stimulate the battery’s activity.
tEMPEratUrE thrEShOLD*
The battery’s internal chemical reaction will cause the temperature of the battery to rise. If the
temperature limit is reached, the process will be terminated.
* This function is available by connecting optional temperature probe, which is not included in the
package.
PC BaSED anaLySIS USIng USB COMMUnICatIOn**
LiPro Quad 6 PC based program can analysis the characteristic of the battery via USB port. It shows
a graph of voltage, current, capacity curves. It also shows the individual voltage of each cell in the
Lithium battery pack.
**This function is available by connecting optional PC-LINK USB adaptor, which is not included in the
package.