10
www.jperkinsdistribution.co.uk
LiXX
V.Type
X.XV
LiPo/LiIo/LiFe
CHK Time 10min
NiMH Sensitivity
D.Peak Default
NiCd Sensitivity
D.Peak Default
USB/Temp Select
Temp Cut-Off 80C
USER SET
PROGRAM
INC
DEC
INC
DEC
INC
DEC
INC
DEC
INC
DEC
Start
Enter
Select USER SET PROGRAM from the main menu by pressing the
“Start/Enter” button
This screen displays the nominal voltage of the Lithium battery.
There are 3 kinds of Lithium battery: LiPo (3.7V) LiIo (3.6V) or LiFe
(3.3V). It is very important that you choose the correct battery
type in this menu before trying to charge it. Using the wrong
setting could cause the battery to explode during the charge
process.
The safety timer automatically begins running when the charge
process starts. This function is to prevent over charge of the
battery if it proves to be faulty, or if the termination circuit does
not detect a pe
ak. The timer limit should not be set lower than the
time needed to allow a full charge of the battery.
These settings show the trigger voltage for automatic charge
termination of NiMH and NiCd batteries. The values can be set
between 5-20mV/cell. If the trigger voltage is set too high there is
a danger of over charging the battery; if it is set lower, there is a
possibility of premature termination. Please refer to the technical
specification of the battery supplied by the manufacturer.
Default settings: NiCd - 12mV/cell
NiMH: - 7mV/cell
An optional feature using a temperature probe (not supplied)
contacting the surface of battery. The temperature cut-off can
be on or off. If it is on, set the maximum temperature at which
the charger should allow battery to reach during charge. Once a
battery reaches this temperature during charge, the process will
be terminated to protect the battery.
uSer Set program optIon
As default, this charger will be set to typical user settings when it is connected to a 12V battery for
the first time. This settings menu can be accessed by selecting
User Set Program
from the main
menu by pressing the “Start/Enter” button.
Scroll through the different options in the User Set Program menu by pressing the “INC” or “DEC”
buttons.
If you need to alter the settings for an option press the “Start/Enter” button to make it blink then
change the value with “DEC” or “INC” button. The value will be stored by pressing “Start/Enter”
button.
To exit from the
User Set Program
menu press the “Batt type/Stop” button.