JP EnErG Lipro Quad 6 Скачать руководство пользователя страница 25

23

www.jperkinsdistribution.co.uk

SAVE [01]   NiMH
14.4V    3000mAh

NiMH  CHARGE  At*
CUR LIMIT    5.0A

NiMH DISCHARGE*
4.0A       11.0V

NiMH CYCLE     *
DCHG>CHG       3

Save...

PROGRAM SELECT

SAVE DATA

Press and hold “Start/Enter” 

for 3 seconds

INC

DEC

INC

DEC

Start

Enter

Select PROGRAM SELECT SAVE DATA from the 

main menu by pressing the “Start/Enter” button.

 Set up the charge current for 

Manual

 mode or 

the current limit for 

automatic

 mode.  Toggle 

between automatic and manual by pressing “Start/

Enter” and then the “INC” and “DEC” buttons 

simultaneously.

Save data program

The LiPro Quad 6 charger has the capacity to store up to 5 charge programs per charger (a 

total of 20), useful for storing programs for specific batteries.
These programs can be recalled at any time without having to set up the program again.

Programs can be saved for the following types of battery only: 

LiPo, NiMH, NiCd and Gel cell (Pb, lead acid).

The parameters set up in this program do not affect the charge or discharge process, they 

only represent the specifications of the battery.

Example: niMh battery SaVE set-up:

Use this screen set up the battery specifications.  

To alter a value press the “Start/Enter” button and 

then press “INC” or “DEC”. To enter the settings 

for the program press and hold the “Start/Enter” 

button.

 Set up the discharge current and final voltage.

 Set up the sequence of charge to discharge cycles 

and the number of cycles.

Press and hold “Start/Enter” to save the program.

Press and hold “Start/Enter” 

for 3 seconds

note: for the different batteries these screens will be different but the instructions on how to 

change values and save the data is the same.

Содержание Lipro Quad 6

Страница 1: ...Instruction Manual V10 09...

Страница 2: ...aste Electrical and Electronic Equipment Do not dispose of this product in household waste At the end of the products life dispose of it at a designated collection point for the recycling of waste ele...

Страница 3: ...it does not required a separate balancer when charging Lithium batteries LiPo LiIon LiFe for voltage balancing The twin fan cooling system is so smart and efficient The fan speed is controlled by int...

Страница 4: ...s with 4mm connectors and crocodile clips for direct 11 15V DC battery connection LCD Screen Menu control buttons INPUT 11 15V Twin ventilation fan with temperature sensor control Battery sockets Univ...

Страница 5: ...uad 6 can monitor and balance each cell of the battery individually An error message will be shown and the process will be ended automatically if the voltage of any single cell is abnormal Adaptable t...

Страница 6: ...battery s activity Temperature threshold The battery s internal chemical reaction will cause the temperature of the battery to rise If the temperature limit is reached the process will be terminated T...

Страница 7: ...de models always remove them before charging Make sure you know the specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set...

Страница 8: ...circuits Make sure you know which way your battery pack is wired and be aware of it s capacity In a parallel circuit the capacity of the pack is multiplied by the number of cells but the voltage stays...

Страница 9: ...e cut off level 3 0V cell or higher LiFe Voltage level 3 3V cell Max charge voltage 3 6V Allowable fast charge current 4C or less Discharge voltage cut off level 2 0V cell or higher Gel Cell Pb Lead A...

Страница 10: ...a 2 cell pack can be 3 7V in parallel or 7 4V in series Have you checked that all connections are firm and safe Make sure there are no intermittent contacts at any point in the circuit Selecting a Pro...

Страница 11: ...g a battery it is absolutely essential to check one last time that you have set the parameters correctly If the settings are incorrect the battery may be damaged and could even burst into flames or ex...

Страница 12: ...tween 5 20mV cell If the trigger voltage is set too high there is a danger of over charging the battery if it is set lower there is a possibility of premature termination Please refer to the technical...

Страница 13: ...t you of changes in the charge process including errors These functions can be switched ON or OFF independently This function monitors the voltage of the input battery used to power this charger If th...

Страница 14: ...s by more than 1 during charge at any time the battery will explode The charge current nominal voltage and cell count set on the charge program must always be correct for the battery to be charged Lit...

Страница 15: ...blink then change the value with DEC or INC button The value will be stored by pressing Start Enter button 3 Once the settings are correct press and hold the Start Enter button to begin the charge pro...

Страница 16: ...lance the voltages How to charge Follow steps 1 6 of the Lithium Charge program Viewing the Voltage of Individual Cells This charge process allows you to monitor the voltage of individual cells whilst...

Страница 17: ...ed to ensure you have the correct type of battery selected for the type you are about to charge if you have the wrong type selected you need to exit the charge program immediately and change the setti...

Страница 18: ...ell count of the battery pack to be charged NOTE At this stage you need to ensure you have the correct type of battery selected for the type you are about to charge if you have the wrong type selected...

Страница 19: ...he charge program immediately and change the setting in the USER SET PROGRAM menu WARNING THE CURRENT VALUE ON THE LEFT OF THE SECOND LINE MUST NOT EXCEED 1C THE FINAL VOLTAGE ON THE RIGHT SHOULD NOT...

Страница 20: ...button to make the current field flash and then press and hold the INC and DEC buttons simultaneously 3 Manual The current field in the manual setting is charge current If you need to alter the charg...

Страница 21: ...he current field in the manual setting is discharge current and the voltage field is final pack voltage If you need to alter the discharge current or voltage press the Start Enter button to make it bl...

Страница 22: ...ok similar to this The information on the left of the second line denotes the sequence of the cycle and the value on the right of the second line denotes the number of cycles 1 5 2 If you need to alte...

Страница 23: ...g the INC or DEC buttons and press the Start Enter button to select The display should look similar to this The charge current is displayed in the lower left The nominal voltage is displayed in the lo...

Страница 24: ...urrent ranges from 0 1 to 1A The voltage should match the voltage of the battery to be discharged 2 If you need to alter the current or the voltage press the Start Enter button to make it blink then c...

Страница 25: ...ms can be recalled at any time without having to set up the program again Programs can be saved for the following types of battery only LiPo NiMH NiCd and Gel cell Pb lead acid The parameters set up i...

Страница 26: ...e INC and DEC keys 3 Once you have scrolled to the program required press and hold the Start Enter button Viewing Extra Charge Discharge Data During the charge discharge process extra information can...

Страница 27: ...e voltage of one of the cells in a Lithium battery pack has risen above the maximum voltage Check the voltage of the cells individually There is a bad connection at the individual connector Check the...

Страница 28: ...European agents J Perkins Distribution Lenham England www jperkinsdistribution co uk...

Отзывы: