Electromagnetic Compatibility Information

Electromagnetic Compatibility Information

Electromagnetic Compatibility Information

NOTE 1At 80 MHz and 800 MHz, the higher frequency range applies.NOTE 2 
These guidelines may not apply in all situations. Electromagnetic propagation is 
affected by absorption and reflection from structures, objects and people.

a The ISM(industrial, scientific and medical) bands between 0,15 MHz and 80 MHz 
are 6,765 MHzto6,795 MHz;13,553 MHz to 13,567 MHZ;26,957 MHz to 27,283 
MHz; and 40,66 MHz to 40,70 MHz. The amateur radio bands between 0,15 MHz 
and 80 MHz are 1,8 MHz to 2,0 MHz,3,5 MHz to 4,0 MHz,5,3 MHz to 5,4 MHz,7 
MHz to 7,3 MHz,10,1 MHz to 10,15 MHz,14 MHz to 14,2 MHz,18,07 MHz to 18,17 
MHz,21,0MHz to 21,4MHz,24,89 MHz to 24,99 MHz,28,0 MHz to 29,7 MHz and 
50,0 MHz to 54,0 MHZ.

b The compliance levels in the ISM frequency bands between 150 kHz and 80 MHz 
and in the frequency range 80 MHz to 2,7 GHz are intended to decrease the 
likelihood that mobile/portable communications equipment could cause 
interference if it is inadvertently brought into patient areas. For this reason, an 
additional factor of 10/3 has been incorporated into the formulae used in 
calculating the recommended separation distance for transmitters in these 
frequency ranges.

c Field strengths from fixed transmitters, such as base stations for radio(cellular/
cordless) telephones and land mobile radios, amateur radio, AM and FM radio 
broadcast and TV broadcast cannot be predicted theoretically with accuracy. To 
assess the electromagnetic environment due to fixed RF transmitters, an 
electromagnetic site survey should be considered. If the measured field strength in 
the location in which the device is used exceeds the applicable RF compliance level 
above, the device should be observed to verify normal operation. If abnormal 
performance is observed, additional measures may be necessary, such as 
re-orienting or relocating the device.

d  Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 
3 V/m.

Table 3 continued

Electromagnetic Compatibility Information

6

Beep Alarm

If

 

thermometer

 

detects

 

a

 

body

 

temperature

 ≥ 

37

.

8

(

100

.

0

under

 

forehead

 

mode

there

 

will

 

be

 

a

 

long

 

beep

 

sound

 

followed

 

by

three

 

short

 

beep

 

sound

 

to

 

warn

 

the

 

user

.

语音款没有

beep,

台湾定制蜂鸣和振动共存,在蜂鸣关了之后振动打开,常规款有语音的不能有这个发烧报警

Содержание DET-3015b

Страница 1: ...light emitted from the forehead It converts the measured heat into a temperature reading displayed on the LCD When properly used it will quickly assess your temperature in an accurate manner Indicatio...

Страница 2: ...the Illustration For Use Voice The thermometer will broadcast the result after finishing measurement Language Switch Please see the Real Time Clock Setting to learn how to change between Chinese and E...

Страница 3: ...shing automatically Setting Press and release the to advance one hour until the correct hour appears After the hour is set press Button the Minute figure is flashing automatically Setting Button Set t...

Страница 4: ...ly 30 minutes prior to use 12 It is not intended for use in the oxygen rich environment and presence of flammable anesthetic mixture with air oxygen or nitrous oxide To measure object temperature 1 yo...

Страница 5: ...dest reading stored in memory See Figure 7 Each memory also records the measurement date time mode icon Bluetooth requirements The thermometer requires a bluetooth device with Bluetooth 5 0 or later A...

Страница 6: ...d sensors can degrade performance or cause other problems 2 For cleaning 1 Soak a clean soft cloth in drinking water wring it out and then wipe the thermometer including probe no less than 3 times 2 V...

Страница 7: ...the manufacturer s representative for assistance if needed in setting up using or maintaining the thermometer or to report unexpected operation or events Troubleshooting Symbol Explanation Caution 95...

Страница 8: ...arty responsible for compliance could void the user authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to...

Страница 9: ...Hz are intended to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought into patient areas For this reason an additional factor...

Страница 10: ...immunity of this equipment and result in improper operation Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm...

Отзывы: