4. FUNCTIONS

1. Functions for protection:

 

 

OVP (over voltage protection): over voltage protection by 25 to 30 V,  

 

the LED display shows “OVP“ like the picture below.

 

OTP (over temperature protection): with a temperature of over 80 °C  

 

the LED display shows “OTP“.

 

OPP (over power protection): With a power of over 35 W the  

 

 

LED display shows “OPP“.

 

After the load is in the protection mode, you have to set the  

 

 

recovery mode for the output.

 

 

Display of voltage, current and power

 

 

Intelligent fan, with a power of 10 W or a temperature of 40 °C the  

 

fan starts automatically to cool the device

 

Precise multiloop potentiometer to adjust the current accurately up   

 

to 0.01 A.

 

You can set the standard start status freely.

2. Trigger function:

 

The device can trigger QC2.0, QC3.0, Huawei FCP, Samsung AFC 9V  

 

and other quick charger modes.

3. Detection of quick charger function :

 

You can use the Auto mode to identify if your quick charger has the  

 

quick charger function.

4. Power-On automatic trigger function:

 

With this function you can trigger the quick charger after the start  

 

of the device and activate the load automatically. It suits either for  

 

batch tests by older charging units.

Содержание JT-HD35

Страница 1: ...resistance suits perfectly for example to test how much power your USB charging unit really has The load resistance can be powered with up to 35 W The current can be adjusted with a built in trimmer...

Страница 2: ...35 W 4 digit segment display fan speed 8000 RPM 10 connections USB2 0 micro USB USB Typ C dimensions 81 x 41 x 28 cm weight 52 g 3 PIN ASSIGNMENT USB 2 0 USB C micro USB Aluminium heatsink Fan LED seg...

Страница 3: ...th a power of 10 W or a temperature of 40 C the fan starts automatically to cool the device Precise multiloop potentiometer to adjust the current accurately up to 0 01 A You can set the standard start...

Страница 4: ...tton to switch the load output with the next start on or off display for activated load at the start display for deactivated load 6 TRIGGER FUNCTION The trigger decoy function is the function to start...

Страница 5: ...of the trigger mode hold down Shifting to the load mode Starting and Stopping of the trigger mode Hold down the trigger button to switch between trigger and load mode If you switch from the trigger mo...

Страница 6: ...d appliance to a registration office Before you hand over the old appliance you must remove used batteries and accumulator which are not enclosed of the device Return options As the end user you can w...

Страница 7: ...hone and ticket support system to answer these E Mail service joy it net Ticket System http support joy it net Telephone 49 0 2845 98469 66 10 17 o clock For more information visit our website www joy...

Отзывы: