27
ENGLISH
14 ALARM MANAGEMENT
Failure is signalled by means of the following procedure:
1) sound warning (beep),
2) lighting up of one of the following icons: ,
3) in the case of an alarm, the stove will be extinguished,
4) holding the “cancel” button displays the code of
the alarm:
CODE OF
ALARM/
MESSAGE
DESCRIPTION
POTENTIAL CAUSES
LED
E001
Control keyboard damaged
Damage to control keyboard
E002
Remote control signal not received
Damage to control keyboard
E004
Connection interrupted
Cutting off or disconnection of cable connecting
the card to the control keyboard.
Ignore this alarm if it is displayed during change of
configuration.
E101
Ignition failed
No pellet
Pellet quality
Malfunction of ignition system
Dirty brazier
E105
Pellet sensor alarm
Pellet sensor damaged or disconnected
E108
*
Safety alarm
Open door or funnel
E109
Pressure alarm or tripping of circuit
breaker
Dirty smoke extraction system
Wear of gaskets
Insufficient air for combustion
Overheating of pellet container
E110
Malfunction of temperature sensor
Damaged air sensor
E111
Malfunction of smoke sensor
Damaged smoke temperature sensor
A001
Insufficient pellet level (flashing icon) Pellet running out
A002
Warning concerning planned
maintenance (flashing icons)
The stove requires regular maintenance, which
must be performed by specialised personnel.
A004
Low battery
The back-up battery (mod. CR2032) on the
electronic board is low
A007
Malfunction of pressure sensor
(flashing icon)
Malfunction of pressure sensor or card
----
Cleaning the stove
Dirty combustion chamber, brazier or smoke
extraction system.
Pollution or disconnection of pressure reading
cables.
Pollution of inlet for combustion air.
----
Ignition failed
No pellet; igniter damaged; worn gasket; improper
brazier positioning
* Only in the case of models equipped with safety micro-switches in the door or on the container’s cover.
After the message is checked, the alarm can be cleared by
pressing the ignition/extinguishing button for several
seconds.
If code “E108” or “E109” is displayed, manually restart
the thermostat located on the rear of the stove, then
clear the alarm (fig. 14.1) (this activity must be performed
according to the guidelines of the authorised seller). The
stove can be reignited.
Before proceeding with a new ignition, check that:
• the stove is cold
• the brazier is clean and free of any residue of ash or
granules
• the brazier is correctly positioned in its seat
• the doors of the firebox and the tank are perfectly
closed
fig� 14�1