4
138301_Rev_G 10.4.11
Jøtul GF
400
This appliance is an atmospherically-vented gas
fireplace heater designed only for vertical venting
directly to the outside of the house, using listed, Type
B-vent pipe.
Input Rates
THIS FIREPLACE IS SHIPPED FROM THE FACTORY
FOR USE WITH NATURAL GAS ONLY. FOR USE
WITH PROPANE, THE APPLIANCE MUST FIRST BE
CONVERTED USING #156005 FUEL CONVERSION KIT
PROVIDED. CONVERSION SHOULD BE MADE BEFORE
THE APPLIANCE IS INSTALLED. SEE PG. 11.
With Short Legs, reduce height by 2 1/4” ( 51 mm)
13”
330 mm
Rear Exit
23 1/2”
597 mm
CL
6 3/4”
171 mm
24”
609 mm
28”
711 mm
26 3/4”
679 mm
13”
330 mm
4 1/2”
114 mm
13 1/4”
336 mm
CL
26 1/2”
673 mm
LC
BV Sebago
Specifications
Manifold Pressure:
MIN.
MAX.
Natural Gas:
1.2 WC (.30 kPa) 3.8 WC (.95 kPa)
Propane:
2.9 WC (.722 kPa) 11.0 WC (2.74 kPa)
Piezo Ignitor / Standing Pilot
Inlet Pressure:
MIN.
MAX.
Natural Gas:
5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane:
12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa)
Propane
40,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input
Natural Gas
40,000 BTU/hr. maximum input
22,000 BTU/hr. minimum input