Jøtul GF 400 BV Sebago Скачать руководство пользователя страница 23

23

138301_Rev_G  10.4.11

High Altitude Adjustment

Installations burning natural gas and located at altitudes 

from 2000 - 4500 ft. (610 M - 1370 M),

 require compensa-

tion for the thinner air (less volume of air per cubic foot). 

Higher altitudes affect the atmospheric pressure and heat 

value of gaseous fuels.  The lower oxygen content in the 

air and the lower gas viscosity require the use of a differ-

ent orifice to achieve efficient, clean combustion at the 

burner tube.  For high altitude installations, consult the 

local gas distributor or the authority having jurisdiction 

for proper rating methods.  If the installer must convert 

the unit to adjust for varying altitudes, use Jøtul High 

Altitude Kit, #155885-LP or # 155895 NG.

DO NOT DERATE THE BURNER FOR PROPANE.

In the U.S:  THE DERATING KIT MUST BE INSTALLED BY 

AN AUTHORIZED SERVICE TECHNICIAN IN ACCORDANCE 

WITH THE MANUFACTURER’S INSTRUCTIONS AND ALL 

CODES AND REQUIREMENTS OF THE AUTHORITY HAV

-

ING JURISDICTION. THE INFORMATION STICKER MUST 

BE COMPLETED BY THE INSTALLER AND APPLIED TO THE 

APPLIANCE AT THE TIME OF THE CONVERSION. THE QUALI

-

FIED SERVICE AGENCY PERFORMING THIS WORK ASSUMES 

RESPONSIBILITY FOR THIS DERATING.
In Canada: This unit has been tested for installation at 

high altitudes in accordance with Canadian test standard 

CAN/CGA-2.17. THE DERATING SHALL BE CARRIED OUT IN 

ACCORDANCE WITH THE REQUIREMENTS OF THE PROVIN

-

CIAL AUTHORITIES HAVING JURISDICTION AND IN ACCOR-

DANCE WITH THE REQUIREMENTS OF THE CAN1-B-149.1 

AND .2 INSTALLATION CODE.

 

 

AVERTISEMENT:

CET EQUIPEMENT DE CONVERSION SERA INSTALLE PAR 

UNE AGENCE QUALKFIEE DE SERVICE CONFORMENMENT 

AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES 

ET CODES APPLECABLES DE L’AUTORISES AVOIR LA JURI

-

DICTION.  SI L’INFORMAITON DANS CETTE INSTRUCTION 

N’EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU 

PRODUCTION DE PROTOXYDE DE CARBONE PEUT RE

-

SULTER LE DOMMAGES CAUSER DE PROPRIETE, PERTE OU 

BLESSURE PERSONNELLE DE VIE.  L’AGENCE QUALIFIEE’ DE 

SERVICE EST ESPONSABLE DE L’INSTALLATION PROPRE DE 

CET EQUIPEMENT.  L’INSTALLATION N’EST PAS PROPRE ET 

COMPLETE JUSQU’A L’OPERATION DE L’APPAREIL CONVERTI 

EST CHEQUE SUIVANT LES CRITERES ETABLIS DANS LES 

INSTRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC 

L’EQUIPEMENT.  
Derating Procedure

1.  Follow Steps 1-10 of the Fuel Conversion procedure 

outlined on pages 11 and 12.

2.  Replace the original orifice with the appropriate orifice 

in the kit: 3.10 mm NG  or #51 LP.

3.  Fill out the high altitude conversion label from the kit 

and attach to the rating plate or gas valve.

4.  Reassemble the firebox components.

5.  It may be necessary to adjust the air shutter on the 

burner tube.  See AIR SHUTTER/FLAME APPEARANCE on 

page 16 for more details.

Figure 51.  Locate 

and remove 

the Air Shutter 

wingnut from 

under the right 

side of the stove.

Figure 52.  

Remove the 

Air Shutter 

and Burner as 

a unit.

Burner Plate

Air Shutter

Air Shutter 

Wingnut

FRONT 

LEG

BACK 

LEG

Mobile Home Installation

The GF 400 BV can be installed for use in a mobile home 

in the U.S. and Canada provided:
1.  The stove is secured to the floor of the mobile home. 

Use Jøtul Floor Bracket Kit #750304.

2.  Provision must be made to secure an electrical ground 

between the stove and the mobile home chassis.

3.  The stove is installed in accordance with Title 24 CFR, 

Part 3280-  Manufactured Home Construction and 

Safety Standard, in the U.S. In Canada, comply with CSA 

Z240.4, Gas Equipped Recreational Vehicles and Mobile 

Housing.

4.  Always contact your local officials about installation 

restrictions and requirements in your area.

THIS APPLIANCE MAY BE INSTALLED AS AN OEM INSTALLA

-

TION IN A MANUFACTURED (MOBILE) HOME AND MUST 

BE INSTALLED IN ACCORDANCE WITH THE MANUFAC

-

TURER’S INSTRUCTIONS AND THE MANUFACTURED HOME 

CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, 

PART 3280. THIS APPLIANCE IS ONLY FOR USE WITH THE 

TYPE OF GAS THAT IS INDICATED ON THE STOVE’S RATING 

PLATE.  A GAS CONVERSION KIT IS PROVIDED WITH THE GF 

300 DV GAS STOVE.

THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMAR

-

KET PERMANENTLY LOCATED, MANUFACTURED (MOBILE) 

HOME, WHERE NOT PROHIBITED BY LOCAL CODES.

 

CET APPAREIL PEUT ETRE INSTALLE DANS UN MAISON 

PREFABRIQUEE (MOBILE) DEJA INSTALLEE A DEMEURE SI 

LES REGLEMENTS LOCAUX LE PERMETTENT.  CET APPAR

-

EIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE 

GAS INDIQUES SUR LA PLAQUE SIGNALETIQUE.  NE PAS 

L’UTILISER AVEC D’AUTRES GAS SAUF SI UN KITDE CON

-

VERSION CERTIFIE EST INSTALLE.

Содержание GF 400 BV Sebago

Страница 1: ...r future reference QUEFAIRESIVOUSSENTEZUNEODEURDEGAZ Ne pas tenter d allumer l appareil Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez Appe...

Страница 2: ...d air intake must be used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructions must remain with the appliance or equipment at the com...

Страница 3: ...space below You may also wish to attach your purchase receipt to this page for future reference MODEL NAME J tul GF 400 BV Gas Stove SERIAL NUMBER _______________________________ DATE OF PURCHASE ____...

Страница 4: ...E APPLIANCE IS INSTALLED SEE PG 11 With Short Legs reduce height by 2 1 4 51 mm 13 330 mm Rear Exit 23 1 2 597 mm C L 6 3 4 171 mm 24 609 mm 28 711 mm 26 3 4 679 mm 13 330 mm 4 1 2 114 mm 13 1 4 336 m...

Страница 5: ...ing if a proposed installation is acceptable Any requirement that is requested by the local authority having jurisdiction that is not specifically addressed in this manual defaults to local code In th...

Страница 6: ...doivent tre avertis des dangers des temp ratures de surface lev es et devraient rester l cart pour viter les br lures ou l inflammation des v tements Young children should be supervised while they ar...

Страница 7: ...Maintain clearances to combustibles as noted above Width 32 81 cm Depth 24 61 cm Height 61 155 cm Approved Wall Pass Through Use only 4 Simpson Dura Vent Wall Thimble 3143 to pass the vent pipe throu...

Страница 8: ...e B cap is required See diagrams page 10 Venting on the Sebago CANNOT be less than 4 in diameter or greater than 4 in diameter Any unused flue or masonry enclosure can be used as a passage way for ven...

Страница 9: ...NENT When installing at an altitude above 2000 the mini mum vertical rise becomes 12 from the draft hood Figure 6 Venting through a masonry chimney Listed termi nation cap required Storm collar requir...

Страница 10: ...90 Elbows Minimum chimney height from Draft Hood is 7 feet Minimum chimney height from Draft Hood is 7 feet Maximum chimney height off Draft Hood is 35 feet Minimum chimney height off Draft Hood is 7...

Страница 11: ...IAN IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTION AND ALL CODES AND REQUIRE MENTS OF THE AUTHORITY HAVING JURISDIC TION FAILURE TO FOLLOW THESE INSTRUC TIONS COULD RESULT IN SERIOUS INJURY OR PROP...

Страница 12: ...two support brackets at the front of the firebox and push the plate back toward the rear of the firebox 11 CHANGE THE PILOT ORIFICE From within the firebox remove the Pilot Head by pulling it straight...

Страница 13: ...rews securely 16 Install the identification labels to the stove so that they can be seen by any person that may be servicing the stove Label A apply to back of stove Label B apply to stove s rating pl...

Страница 14: ...2 0 14 9 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing on that system at test pressures in excess of 1 2 psig 3 5 kP...

Страница 15: ...T THE PILOT ASSEMBLY OPENING Do not pile the embers against the burner skirt edges See fig 24 Figure 20 Engage the holes in the underside ot the Right Log with the peg in the burner skirt Figure 22 In...

Страница 16: ...PLIANCE Figure 26 Valve and Accessory wiring diagram Flame Appearance Air Shutter Adjustment This stove is shipped from the factory equipped to burn Natural gas If the stove has been converted for use...

Страница 17: ...ob located in the center of the valve face Fire intensity can be adjusted up to 50 between the LOW and HIGH settings See fig 29 NO SMOKE OR SOOT SHOULD BE PRESENT CHECK LOG PLACEMENT IF ANY SOOT OR SM...

Страница 18: ...he stove is cold and there are NO hot embers 5 Remember this appliance has a continuous burning pilot flame Exercise caution when using products having combustible vapors Always shut off gas supply wh...

Страница 19: ...ealed according to the manufac turer s instructions provided at the initial installation Burner and Logset Periodically inspect the Firebox Valve Compartment Convection Airways and optional Blower to...

Страница 20: ...6 flange head hex bolts as shown in fig 34 4 Attach the Duct Deflectors using the two 7 x 1 2 screws together with the finger guard mounting screws already in place See 7 and 11 in fig 33 5 Install th...

Страница 21: ...ically when the stove cools down If automatic blower circulation is not desired place the blower control switch in the MANUAL position Figure 37 Blower Wiring Diagram Figure 36 Blower Controls CAUTION...

Страница 22: ...eir own against the wall Push them back against the Rear Panel 6 Reinstall the Logset See page 21 BE CERTAIN THAT NO EMBERS ARE BLOCKING THE PILOT ASSEMBLY OPENING 7 Replace the Glass Frame Slide the...

Страница 23: ...APPAREIL CONVERTI EST CHEQUE SUIVANT LES CRITERES ETABLIS DANS LES INSTRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L EQUIPEMENT Derating Procedure 1 Follow Steps 1 10 of the Fuel Conversion procedure...

Страница 24: ...24 138301_Rev_G 10 4 11 ONLY USE REPLACEMENT PARTS PROVIDED BY AN AUTHORIZED J TUL DEALER Figure 44 J tul GF 400 BV Sebago Illustrated Parts Breakdown...

Страница 25: ...on Kit to Natural Gas 156006 High Altitude Adjustment Kit LP 155885 High Altitude Adjustment Kit NG 155895 45 Gasket Pilot Asy 129670 48 Control Door 2211892 49 Spacer 118040 50 Fender Washer 1 50 dia...

Страница 26: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Страница 27: ...knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this appl...

Страница 28: ...beginning the installation it is important that these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in speci...

Отзывы: