Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove to Combustibles:
Measured from the stove top plate. See figs. 2-4.
For Both Stoves
Rear:
0” (0 mm)
Ceiling:
42” (1066 mm)
Corner:
2” (50 mm)
Sides
:
3” (76 mm)
Minimum Clearances between Vent Pipe and
Combustible Materials:
Horizontal Run:
Off the top of the pipe
2” (50 mm)
Off the sides and bottom
1” (25 mm)
Vertical Run:
All sides
1” (25 mm)
Figure 3. Mantel Clearances - stove flush with fireplace face.
Figure 4. Mantel Clearances - stove set back into fireplace,
6 1/2” maximum.
Figure 2. Alcove Installation Clearances.
CLEARANCE TO REAR WALL = ZERO (0”)
GF 100 DV
or
GF 200 DV
Max. Depth
24”
(610mm)
Alcove Installation
Maximum Alcove Depth:24” (610 mm)
Minimum Alcove Width:
34” (864 mm)
Minimum Ceiling Height
from stove top:
42” (1066 mm)
Min. 34”
(864 mm)
Plinth Kit: 23 3/4 in. (603 mm)
Long Legs: 27 in. (686 mm)
Jøtul GF 100 DV II
Jøtul GF 200 DV II
Nordic QT
Lillehammer
A
A
A
A
A
49 in. (1245 mm)
51 1/2 in. (1308 mm)
B
B
B
B
B
47 1/2 in. (1206 mm)
50 in. (1270 mm)
C
C
C
C
C
46 in. (1168 mm)
48 1/2 in. (1232 mm)
D
D
D
D
D
44 1/2 in. (1130 mm)
47 in. (1194 mm)
E
EE
EE
43 in. (1092 mm)
45 1/2 in. (1156 mm)
F
FF
FF
17 3/4 in. (451 mm)
17 3/4 in. (451 mm)
G
G
G
G
G
22 1/4 in. (565 mm)
24 3/4 in. (629 mm)
Plinth Kit: 23 3/4 in. (603 mm)
Long Legs: 27 in. (686 mm)
Jøtul GF 100 DV II
Jøtul GF 200 DV II
Nordic QT
Lillehammer
A
A
A
A
A
50 in. (1270 mm)
52 1/2 in. (1333 mm)
B
B
B
B
B
48 1/2 in. (1232 mm)
51 in. (1295 mm)
C
C
C
C
C
47 in. (1194 mm)
49 1/2 in. (1257 mm)
D
D
D
D
D
45 1/2 in. (1156 mm)
48 in. (1219 mm)
E
EE
EE
44 in. (1118 mm)
46 1/2 in. (1181 mm)
F
FF
FF
4 1/4 in. (108 mm)
4 1/4 in. (108 mm)
G
G
G
G
G
22 1/4 in. (565 mm)
24 3/4 in. (629 mm)
11.5
9.5
7.5
5.5
Max. Mantel
Depth
Min. Mantel
Depth
Max. Top Trim
Depth = 1
3.5
A
C
E
B
D
F
G
11.5
9.5
7.5
5.5
Max. Mantel
Depth
Min. Mantel
Depth
Max. Top Trim
Depth = 1
3.5
A
C
E
B
D
F
G
Max.
6 1/2