![Jøtul GF 100 DV II Nordic QT Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/jotul/gf-100-dv-ii-nordic-qt/gf-100-dv-ii-nordic-qt_installation-and-operation-instructions-manual_2037552004.webp)
4
Jøtul GF
100
DV II Nordic QT
Specifications
Input Rates
Natural Gas
17,000 BTU/hr. maximum input
9,900 BTU/hr. minimum input
Propane
16,000 BTU/hr. maximum input
8,700 BTU/hr. minimum input
Inlet Pressure:
MIN
MAX
Natural Gas: 5.0 WC (1.24 kPa)
7.0 WC (1.74 kPa)
Propane: 12.0 WC (2.98 kPa) 14.6 WC (3.63 kPa)
Manifold Pressure:
MIN
MAX
Natural Gas: 1.2 WC (0.29 kPa)
3.8 WC (0.94 kPa)
Propane: 2.9 WC (0.72 kPa) 11.0 WC (2.74 kPa)
Piezo Ignitor / Standing Pilot
Weight: 150 lbs.
Jøtul GF 100 DV II Miscellaneous Kit
Contents
• Fuel Conversion Kit - LP ................................. 155628
• Rear Air Intake Restrictor Plate, .... Black -22111092
or Jøtul Iron - 22111085
• Side Air Intake Restrictor Plates, (2) ...... 22099192
or Jøtul Iron - 22099185
* Decorative Wall Shield, Black ................. 22092692
or Jøtul Iron ........ 22092692
Jøtul GF 100 DV II Accessories
• Blower Kit .......................................................... 155631
• Antique Brick Kit .............................................. 155815
• Fuel Conversion Kit - NG ............................... 155629
• Wall Thermostat ............................................ 750003
• Remote Control ............................................... 129706
• Mobile Home Floor Bracket Kit ................... 154342
•
Universal Leg Leveler Kit .............................. 156096
The Jøtul GF 100 DV II Nordic QT is a Direct Vent gas
heater designed as a sealed combustion, air circulat-
ing gas appliance for residential applications. This
appliance is approved for installation using
6 5/8" X 4" direct vent pipe and components from the
following manufacturers:
Simpson Dura-Vent GS
Security Vent, Ltd.
Amerivent Inc.
Selkirk Metalbestos
Metal-Fab, Inc.
ICC, Inc. - ExcelDirect Vent
The Jøtul GF 100 DV II Nordic QT gas stove is de-
signed to burn NATURAL GAS or PROPANE only. It is
shipped from the factory equipped to burn Natural
Gas. If use with Propane is desired, the stove must
first be converted for use with that gas.
Use the LP
Fuel Conversion Kit 155628 included with this stove
See page 14 for instructions.
18 1/4”
464 mm
16 3/4 ”
425 mm
16 3/4”
425 mm
Flue Collar
Centerline
14”
356 mm
21”
533 mm
22 1/4”
565 mm
Leg To
Leg
Содержание GF 100 DV II Nordic QT
Страница 2: ...2...