4.4 Replacement and mounting of the Hydrostatic Release
Mechanism
The Hydrostatic Release Mechanism must be mounted before the
Capsule is placed into the FBR-3 bracket.
To replace the Hydrostatic Release Mechanism, remove the
Capsule from the bracket:
1. Remove the clamp on the locking bolt on the spring-loaded
lower arm.
2. Remove the locking bolt.
3. Whilst holding the Capsule, strain the spring-loaded lower arm
and gently remove the Capsule from the bracket.
4. Now the H20 unit is accessible. Unscrew the plastic bolt (3)
and remove the unit.
5. Replace the old unit with a new one and tag in expiration date
for 2 more years.
6. Screw the new plastic bolt on. Make sure the distance piece
(4,5,6) is in place on the plastic bolt. Tighten the bolt using hand-
force only until rubber seal (5) starts to compress.
Replace the Capsule into the bracket, reversing paragraph 1, 2 and
3.