40
82310_UM_ SVDR_E
6.3.1 EPIRB module error messages
If the self-test detects a fault in the EPIRB module one or more of
the following indications are shown:
1. Flashing LED for 15 sec. followed by one (1) flash, no Xenon
flash:
Error:
Low power on 406 MHz transmitter
2. Flashing LED for 15 sec. followed by two (2) flashes, no Xenon
flash:
Error:
Low battery voltage
3. Flashing LED for 15 sec. followed by three (3) flashes, no
Xenon flash:
Error:
Low power on 121.5 MHz transmitter
4.
Flashing LED for 15 sec. followed by four- (4) flash, no Xenon
flash:
Error:
PLL on 406 Transmitter out of lock
5. Five (5) flashes, no Xenon flash:
Error:
EPIRB module not programmed or programming not complete
Содержание Tron S-VDR CAPSULE
Страница 1: ...www jotron com Tron S VDR CAPSULE USERS MANUAL...
Страница 12: ...12 82310_UM_ SVDR_E Figure 1 1 3 COSPAS SARSAT Signal detection system...
Страница 29: ...82310_UM_ SVDR_E 29 Figure 4 5 a Junction box with lid removed...
Страница 30: ...30 82310_UM_ SVDR_E Figure 4 5 b Junction box with measures...
Страница 42: ...42 82310_UM_ SVDR_E 7 NOTES...
Страница 44: ...Jotron AS P O Box 54 NO 3280 Tjodalyng Norway Tel 47 33 13 97 00 Fax 47 33 12 67 80 www jotron com...