82310_UM_ SVDR_E
2 TECHNICAL SPECIFICATION
Tron S-VDR CAPSULE
STANDARDS
IEC 61097-2 ed.2 annex D and EN 60945 ed.4 2002-08
ENVIRONMENTAL
Temperature range
-20°C to +55°C (operating) -40°C to +70°C (storage)
Degree of protection
10 m depth at 5min
GENERAL
External Supply voltage for
12 – 30 VDC
Current consumption S-VDR 0.25 A at 24VDC
Locator lights
Flashing Xenon light
Test light
Test LED
Frequency range
406,028 / 121,5MHz
Programming
IR port, 2400 bit/s.
Operating life EPIRB
168 hours at -20
°
C
Dimension
L = 570 mm Ø = 188 mm.
Weight
Approx. 3.5 kg
Material housing
Polycarbonate with 10% glass fiber.
Antennas 406.028MHz,
121.5MHz
Built in, vertical polarization, omnidir.
Antenna GPS
Built in GPS patch antenna.
406MHz
Frequency
406.028MHz +2kHz / -5kHz
Output Power
5W
±
2dB
Protocols
MMSI Standard Location (long) Serial EPIRB Standard (long)
Modulation
Phase modulation 1.1
±
0.1rad.
Data Encoding
Bi Phase L.
Stability
Short term:
≤
2*10
-9.
Medium term:
≤
2*10
-9
. Residual
noise:
≤
3*10
-9
.
Bit rate
400 b/s
Содержание Tron S-VDR CAPSULE
Страница 1: ...www jotron com Tron S VDR CAPSULE USERS MANUAL...
Страница 12: ...12 82310_UM_ SVDR_E Figure 1 1 3 COSPAS SARSAT Signal detection system...
Страница 29: ...82310_UM_ SVDR_E 29 Figure 4 5 a Junction box with lid removed...
Страница 30: ...30 82310_UM_ SVDR_E Figure 4 5 b Junction box with measures...
Страница 42: ...42 82310_UM_ SVDR_E 7 NOTES...
Страница 44: ...Jotron AS P O Box 54 NO 3280 Tjodalyng Norway Tel 47 33 13 97 00 Fax 47 33 12 67 80 www jotron com...