34
Tron 40VDR
7.6
HYDROSTATIC RELEASE UNIT REPLACEMENT
WARNING: Only Jotron HRU kit is acceptable for use.
Check expiry date to be valid.
7.6.1 REPLACING THE RELEASE MECHANISM FB40-BRAKET
1.
Release and remove FB-40 top cover.
2.
Remove the EPIRB from the bracket.
3.
Press down and hold in place the spring-loaded bracket plate and remove the
hydrostatic unit by sliding it out of its locking slot.
4. Install the ne
w hydrostatic unit while continuing holding down the spring
loaded bracket plate and sliding the unit into its locking slot.
5.
See chapter 4.2 for mounting the EPIRB in the bracket.
6.
Verify that there is no gap between the bracket and cover.