Tron 40VDR
31
7
PERIODICAL CONTROL AND MAINTENANCE
7.1
EVERY MONTH
•
Self-test (see chapter 6.1 and 6.2)
•
Visual Inspection
- Make sure that nothing prevents the release function of the Tron 40VDR
- Check for defects on the Tron 40VDR, both EPIRB and bracket
- Make sure that the Tron 40VDR are not painted or otherwise covered with
chemicals, oil, etc
- Check that the lanyard is firmly attached to the Tron 40VDR float free capsule
(and not tied to the vessel)
•
Check the expiry dates.
Expiry date location -
EPIRB battery-module
Expiry date location -
HRU (month)
Expiry date location
-
HRU (year)