Tron 40VDR
33
7.3
EVERY 2
ND
YEAR
•
Replace Hydrostatic Release Unit (HRU) including Plastic Bolt. See chapter 7.6 for
description.
•
Mark new expiry date on label.
7.4
EVERY 4
OR 5 YEARS
T
he Tron 40VDR Float Free Capsule is under the regulation according to SOLAS Chap.IV
reg.15.9.2 and IMO MSC.Circ 1039 guideline. The Tron 40VDR Float Free Capsule will
comply to this guideline, either by fulfilling the complete service or be replaced by an
exchange unit.
The interval is dependent on the flag-state administration.
To carry out the battery exchange and SBM-service on the Tron 40VDR Float Free
Capsule the personal need to be trained, certified and authorized by Jotron. In
addition, there is also need for an approval from the VDR manufacturer.
7.5
EVERY 10 YEARS
Jotron strongly recommend replacing both the Tron 40VDR Float Free Capsule and the
Float Free Bracket.