11 Appendix
11.1 Technical data
Electrical power supply:
24 V with negative vehicle earth
Fusing:
At least 15 A (circuit breaker is recommended)
Travel speed at room temperature and 24 V:
7.7 mm/s +/-15%
Tested acc. to:
Electric drive: IP5K4
Control element: IP6K9K
11.2 Dimensions
Order number
Mh
H
A
Module B010X-0Y0000ED
900
560
630
Module B020X-0Y0000ED
850
520
580
Module B030X-0Y0000ED
800
470
530
Module B040X-0Y0000ED
750
430
480
Module B050X-0Y0000ED
700
400
430
Module B060X-0Y0000ED
650
350
380
X = 1 Top plate
Y = 1 S-foot
X = 2 Bottom plate
Y = 2 A-foot
X = 3 Dual plate
Y = 4 T-foot
Y = 6 TC-foot
Load data (per set)
Lifting load
*
Static test load
24 t
50 t
Lift per turn of crank handle,
low gear
*
High gear
*
0.9 mm
15 mm
Crank force with 16 t lifting load
210 N
*
with manual actuation
40
MUB 006 001 M01
(REV-D)
07-2020
Modul E-Drive