TECHNICAL FACTS - VIKING 40
Efficiency (%)
80
Nominal Power (kW)
6,0
Heating surface (approx. m²)
up to 110
Weight (kg)
85
Size (HxWxD mm)
850–920x400x600
Hearth dimensions (HxWxD mm) 250x215x350
Log length (mm)
300–330
Flue pipe dimension (Ø, mm)
120
Distance to combustible material
See page 8-9
CE marked according to standard EN12815
IMPORTANT BEFORE YOU
GET STARTED!
Professional mounting
The manual contains instructions on how to mount and
install the Viking 40. To ensure the function and safety
of the range, we recommend that installation be carried
out by a professional. Contact one of our dealers who
can assist with the installation or recommend a suitable
technician.
Building application
When installing a fireplace and erecting a chimney,
a building application must be submitted to the
municipality's building committee. Contact your building
committee if you are unsure of how the application
works.
Load-bearing substrate
Make sure that the ground floor in your home has
sufficient bearing capacity for a wood burning range with
a chimney. Normally, a wood burning range and chimney
can be placed on a standard wooden frame in a single-
family house if the total weight does not exceed 400 kg.
Hearthstone
Ember coming from the range poses a risk of fire. If you
have a flammable floor in front of your wood burning
range, it must be protected by a hearthstone that covers
at least 300 mm in front of the door and 100 mm along
each side. The hearthstone can consist of, for example,
natural stone, concrete, sheet metal or glass.
The specified safety distances in this manual apply to the
Swedish market. If the wood burning range is installed in
another country, the local regulations must be met.
WARNING! THE WOOD BURNING RANGE GETS VERY HOT
When burning, some areas of the wood burning range become very hot and can cause burns when
touched. Also, be careful with heat radiating through the door glass. If combustible material is placed
closer than the specified safety distance, it can quickly catch fire. Smouldering combustion can cause
rapid gas ignition with the risk of injury to persons and property.
NOTE!
The installation must be inspected by a competent
chimney sweeper before using the range.
Approved for connecting to the chimney with 1/2
stone enclosure (350°). Multiple use (connection to
common chimney) is allowed as long as respective local
regulations are adhered to.
COLOUR
RAL no. 9003/White
RAL no. 7016 / Anthracite