background image

8

•  In alarm status for failed start up, do not try to restart the appliance until the firebox has been thoroughly cleaned.
•  Keep the ventilation grids in the area the appliance is installed in clean conditions.
•  Do not use fuels that are not recommended.
•  Check and periodically clean the fume exhaust pipe, from the appliance to the flue (Union).
•  It is strictly prohibited to start up the product with the combustion chamber door open or allow it to run with the glass broken.
•  In case of need and if any operating problems persist, the user should contact the specialised Technical Assistance Center.

•  Never try to kindle the fireplace by means of ethyl alcohol or any other flammable liquid product..

 

02.3  

SAFETY REGULATIONS FOR EXTRAORDINARY MAINTENANCE AND INSTALLATION

•  The user and/or owner of the product is required, in accordance with the laws in force, to assign the installation and 

maintenance to qualified and specialised operators, and acknowledge the risks and hazards should they fail to observe 

this requirement.

•  The installation of the heat generator and the relative combustion product exhaustion system, the electrical connections, 

the commissioning and extraordinary maintenance services MUST always be performed by qualified and licensed 

professional staff.

•  The product must be installed in accordance with the laws and standards in force in the State, Region or Area in which 

the machine is installed.

•  The system installer MUST issue a Declaration of compliance for the work performed after commissioning the system, 

in accordance with the laws in force related to system safety standards.

•  The installation technician must inform the user on safe equipment use.
•  The installation operator is responsible for the installation and is therefore required to perform the work to top workmanship 

standards.

•  The appliance must be connected to a combustion product exhaustion flue built in accordance with applicable 

standards and certified with a declaration of compliance.

•  Should any installation defects arise during the optional Commisisoning service, the specialised Technical Service 

Center, can refuse to endorse use of the product for safety reasons and submit a written Servicing Report to the User 

informing him that he and the Installation operator shall be jointly liable for any damage to persons, animals or things if 

used.

•  Before installing the machine, the customer and installation operator must ensure that the flooring on which it will be 

positioned is suitably levelled and can support the weight (see 

CHAP.06 - TECHNICAL DATA

). IIf there is any doubt 

on the solidity of the flooring, it is essential to have a Structural Engineer verify relative installation feasibility.

•  Only specialised and qualified personnel may work or carry out checks inside the machine, complying with safety 

regulations.

•  Prior to installation, the user and installer are obliged to check that the mains electrical supply to which the machine will be 

connected, corresponds to the voltage on the identification plate (see 

CHAP.05.2 - PRODUCT IDENTIFICATION

), 

check that the system is sized so as to bear the maximum load required of the product, and also that it is equipped with 

all suitable safety devices to classify the electrical system as COMPLIANT with applicable safety standards. If this is not 

the case, contact a Qualified Technician to adapt the system to required standards.

•  The power cord plug must be connected only AFTER the conclusion of the installation and assembly of the device, and 

must remain accessible after installation if the device does not have a suitable and accessible double-pole switch.

•  Personnel assigned to handling the machines and equipment must always wear industrial gloves and boots.
•  The Maintenance Operator must recommend the Customer to sign an annual maintenance contract for the product, so 

as to maintain the levels of safety and efficient performance of the product.

•  The Maintenance Operator must check the working hours of the product between one maintenance intervention and 

another, to verify the actual work load of the machine. The actual hours of operation shall be reset at the end of the 

Technical intervention and indicated on the Servicing Report.

Содержание SUPERJOLLY EVO 68X50 4S

Страница 1: ...ept by the purchaser Wood burning air inset fireplace UNIVERSALJOLLYEVO604S UNIVERSALJOLLYEVO68X504S UNIVERSALJOLLYEVO68X584S UNIVERSALJOLLYEVO804S SUPERJOLLYEVO604S SUPERJOLLYEVO68X504S SUPERJOLLYJOL...

Страница 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Страница 3: ...NSPORT 10 CHAP 04 ECOLOGICAL REGULATIONS 11 04 1 DISPOSAL OF THE MACHINE 11 CHAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATI...

Страница 4: ...itten permission of Jolly Mec Caminetti S p A The technical directions for installation contained in this manual should be considered as basic requirements Regulations in some countries may be more re...

Страница 5: ...EN 60335 1 Household and similar electrical appliances Safety General requirements EN 60335 2 102 Household and similar electrical appliances Safety Particular requirements for gas oil and solid fuel...

Страница 6: ...ight to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER S LIABILITY AND WARRANTY CONDITIONS Upon the deliver...

Страница 7: ...ry or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of the...

Страница 8: ...ation defects arise during the optional Commisisoning service the specialised Technical Service Center can refuse to endorse use of the product for safety reasons and submit a written Servicing Report...

Страница 9: ...produce its systems with the greatest competence regarding safety and consulting all the directives laws and regulations available there are still if minor some residual risks during the phases of TRA...

Страница 10: ...retailer as soon as possible 03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SA...

Страница 11: ...tive 2012 19 UE waste electrical and electronic equipment WEEE information for users The crossed out wastebasket symbol on the appliance means that at the end of its useful lifespan the product must b...

Страница 12: ...S inset fireplace also feature a combustion chamber in Fireflector HD which in addition to improving the aesthetic appearance also contribute to guaranteeing a high chamber temperatures level hence re...

Страница 13: ...os CO emissioni CO emissions CO emission Emission de CO Emisi n de CO Tensione Frequenza nominale Rated voltage frequency Spannung Nennfrequenz Tension Fr quence nominale Tensi n Frecuencia nominal Te...

Страница 14: ...400 1500 mm Energy efficiency class A A A A Description Superjolly EVO 60 4S Superjolly EVO 68X50 4S Superjolly EVO 68X58 4S Superjolly EVO 80 4S UM Burnt heat output 7 4 8 6 9 9 11 5 kW Nominal heat...

Страница 15: ...e best fuel is air dried untreated wood with a humidity of 15 18 beech hornbeam oak and acacia are highly recommended The wood must be stored outdoors in a protected dry and well ventilated area Exces...

Страница 16: ...1B SuperJolly EVO 4S models 2 Electronic control unit 3 Rock wool matting for boiler insulation For UniversalJolly EVO 4S only 4 Heat proof glove 5 Fan 410 m3 h 6 Support various models only for Univ...

Страница 17: ...UNIVERSALJOLLY EVO 68X58 4S 680 442 5 585 5 472 5 UNIVERSALJOLLY EVO 80 4S 800 562 5 585 5 472 5 SUPERJOLLY EVO 60 4S 600 362 5 500 5 472 5 SUPERJOLLY EVO 68X50 4S 680 442 5 500 5 472 5 SUPERJOLLY EVO...

Страница 18: ...nternal section which is preferably circular square or rectangular sections must have rounded corners with a radius of no less than 20 mm must have an internal section that is constant free and indepe...

Страница 19: ...d Running other air ducts and installation pipes inside the exhaust pipes even if oversized is forbidden One or more airtight reading points are recommended on the flue to check emissions after instal...

Страница 20: ...the passage of air intake ducts inside the fume evacuation system is prohibited Fig 4 6 Organize the air intakes by choosing one of these options a Combustion air intake connected with the outside wit...

Страница 21: ...he outside in the room of the installation Then you have to take apart the central opening b Fig 5 it is necessary to screw off the screw and to remove the combustion air regulation lever When the cen...

Страница 22: ...ENANCE Repeat these operations in the reverse order to reposition it 8 If possible pad with rock wool between the existing chimney flue and the stainless steel pipe to prevent a return of the flue gas...

Страница 23: ...ctrically connected the probe has been connected to the control unit and the device operating functions have been tested close all access to the compartment using the parts indicated in section 12 fol...

Страница 24: ...amic fibre rock wool and can come in different forms sheets mattresses Its specific weight must be equal or greater than 245 kg m3 with a temperature threshold of about 1000 C and thermal conductivity...

Страница 25: ...vailable 1 Flammable Wall 2 Flammable floor 3 Flammable ceiling 4 Fireplace cladding in not flammable material Installation distances from flammable materials A Minimum air distance from inflammable s...

Страница 26: ...le exhaust vents for hot air at least 2 x 80 cm Regulation of comburent air Flexible aluminium pipes for hot air ducting 100 mm Recirculation grid obligatory hood 450 cm 100 mm from the ceiling Fume e...

Страница 27: ...pipes to deliver the air is very dangerous because the high temperatures could deform them and generate harmful gases Where the ducting pipes cannot be embedded they can be concealed with a false cei...

Страница 28: ...onnection or Y connection optional and connect the two top outlets as well as the ducting WARNING Fig 2 Installation with internal fan air intake Provide for recirculation of hot air in the room see C...

Страница 29: ...n and functioning then turn the comburent air regulating lever to position 1 Fig 1 Small pieces of wood maximum LxHxW 35x4x4 cm must be used to light the fire stacking them on the fireplace grate as s...

Страница 30: ...arge To achieve the declared nominal heat output adjust the unit as follows Model Wood quantity Dimension Comburent air record Rechar ging time Universaljolly EVO 60 4S Superjolly EVO 60 4S 2 identica...

Страница 31: ...the same room excluded of the type C according to UNI 10683 The device must not be used to burn anything other than the recommended fuels as the combustion by products could corrode the device or the...

Страница 32: ...grate and use a brush or sharp tool to clean away any residues A vacuum cleaner can also be used Put everything back in place Glass Use specific products Be careful not to use overly aggressive produc...

Страница 33: ...carry out these operations the appliance must be disconnected from the mains wait until the appliance is cold and comply rigorously with the safety regulations in force WARNING Flue gas deflector To r...

Страница 34: ...excluded of the type C according to UNI 10683 Load the wood when there is no flame Place the baffle correctly see CHAP 08 5 ASSEMBLY SEQUENCE The outside air inlets and or the flue are partially or co...

Страница 35: ...ENGLISH NOTES 35...

Страница 36: ...SM140 EN REV01 2019_01 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: