background image

 

2TLC172075M0201, rev. A 

www.jokabsafety.com 

2012-09-27  

Read and understand this document 

Please read and understand this document before using the products. Please consult your ABB/JOKAB SAFETY 
representative if you have any questions or comments. 

WARRANTY 

ABB/

JOKAB SAFETY’s exclusive warranty is that the products are free from defects in materials and workmanship 

for a period of one year (or other period if specified) from date of sale by ABB/JOKAB SAFETY.  

ABB/JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, 
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF 
THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED 
USE. ABB/JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. 

LIMITATIONS OF LIABILITY 

ABB/JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL 
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, 
WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  

In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on 
which liability asserted.  

IN NO EVENT SHALL ABB/JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER 
CLAIMS REGARDING THE PRODUCTS UNLESS ABB/

JOKAB SAFETY’S ANALYSIS CONFIRMS THAT THE 

PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO 
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

SUITABILITY FOR USE 

ABB/JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply 
to 

the combination of products in the customer’s application or use of the product. At the customer’s request, 

ABB/JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of 
use that apply to the products. This information by itself is not sufficient for a complete determination of the 
suitability of the products in combination with the end product, machine, system, or other application or use.  

The following are some examples of applications for which particular attention must be given. This is not intended 
to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be 
suitable for the products:  

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not 
described in this document.  

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, 
amusement machines, vehicles, and installations subject to separate industry or government regulations.  

Systems, machines, and equipment that could present a risk to life or property.  

Please know and observe all prohibitions of use applicable to the products.  

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY 
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE ABB/JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE 
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

PERFORMANCE DATA 

While every effort has been taken to ensure the accuracy of the information contained in this manual ABB/JOKAB 
SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and 
improvements without notice. Performance data given in this document is provided as a guide for the user in 
determining suitability and does not constitute a warranty. It may represent the result of ABB/JOKAB 

SAFETY’S 

test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to 
the ABB/JOKAB SAFETY Warranty and Limitations of Liability. 

Содержание JSNY5

Страница 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www jokabsafety com Original instructions JSNY5 Safety interlock switch ...

Страница 2: ...FETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attentio...

Страница 3: ...s 4 Special notes 4 2 Overview 5 General description 5 Safety regulations 5 Function description 6 3 Connections 7 4 Installation and maintenance 8 Installation 8 Installation precautions 10 Maintenance 10 5 Operation 11 6 Model overview 12 Accessories 12 7 Technical data 13 Dimensions 14 8 EC Declaration of conformity 15 ...

Страница 4: ...sonnel Prerequisites It is assumed that the reader of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of safety devices and safety locks Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may ...

Страница 5: ...refully read through this entire manual before using the device The devices shall be installed by a trained electrician following the Safety regulations standards and the Machine directive Failure to comply with instructions operation that is not in accordance with the use prescribed in these instructions improper installation or handling of the device can affect the safety of people and the plant...

Страница 6: ...d using multi coding to GS ET 15 The switch cannot be defeated by screwdrivers magnets or any other mechanism The positive forced disconnect contacts gives a high safety level By combining the JSNY5 with one of our suitable safety relays like the RT series the safety PLC Pluto or Vital Tina the requirements for both hatch and gate switch supervision can be fulfilled To obtain PL e the highest safe...

Страница 7: ... 12 and 21 22 are positive forced disconnected and should therefore be used for the safety function Overlapping contact 33 34 The overlapping contact 33 34 enables operational status indication of e g incorrect adjustment of switch before the positive forced disconnect NC contacts open Actuator withdrawn Actuator inserted Traction travel Contact open Contact closed ...

Страница 8: ... fit which seals the mounting screws prevents unauthorised dismantling of the actuator assembly The cover plate must be mounted as it also prevents over travel of the switching mechanism Fixing dimensions for all actuators 40 mm with M5 screw Minimum opening radius for the actuator when mounted on a hatch is 150 mm for a fixed actuator or 50 mm in the adjustable direction for a flexible actuator C...

Страница 9: ...imum safety distance is calculated according to EN ISO 13855 Positioning of safeguards with respect to the approach speeds of parts of the human body The minimum safety distance is calculated according to the formula S K x T C Where S minimum safety distance mm K approach speed of a human body 1600 mm s T the total time from opening of the guard until the hazardous machine movement has stopped i e...

Страница 10: ...ctions and the mechanics shall be tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 In order to maintain the safety level regular inspections for tear and wear as well as fixing and alignment of switch actuator brackets doors etc should be carried out In case of breakdown or damage to the product contact the nearest ABB Jokab Safe...

Страница 11: ...e switch head and opened as soon as the actuator is withdrawn The force required to insert the actuator into or extract the actuator out of the switch head depend on the model Actuating forces Extraction force JSNY5A approx 10N JSNY5B approx 30N Actuator insertion force Force Eject FE Actuator will be ejected automatically F min 10N ...

Страница 12: ...ormation contact your local ABB Jokab Safety sales office Type Article number Description Spare part 2TLJ020032R0000 Steel key for JSNY5 Accessory 2TLJ020032R0600 Flexible key for JSNY5 Spare part 2TLJ020033R0000 Lid for JSNY5 Accessory 2TLJ020054R0100 Tina 2A with M20 connection for dynamic loop Accessory 2TLJ020054R1100 Tina 2B with cable connection Accessory 2TLJ020054R0200 Tina 3A with M12 and...

Страница 13: ...e JSNY5A 10 6 switch operations JSNY5B 10 5 switch operations Max switching frequency 30 min Min opening radius for actuator on a hatch Fixed actuator 150 mm Flexible actuator 50 mm adjustable direction Max approach speed 0 2 m s Safety Harmonized standards Conformity European Machinery Directive 2006 42 EC EN ISO 12100 1 2003 A1 2009 EN ISO 12100 2 2003 A1 2009 EN 954 1 1996 EN ISO 13849 1 2008 E...

Страница 14: ...2TLC172075M0201 rev A 14 www jokabsafety com 2012 09 27 Dimensions JSNY5 dimensions NB All measurements in millimetres ...

Страница 15: ...2TLC172075M0201 rev A 15 www jokabsafety com 2012 09 27 8 EC Declaration of conformity ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www jokabsafety com ...