![Johnston VS501 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/johnston/vs501/vs501_maintenance-section_2025219017.webp)
All Copyright and rights are the property of Johnston Sweepers Ltd
MA1:13
V Range 501
l
651
l
801 Maintenance Manual
Johnston Sweepers Limited
Chapter - Scheduled Maintenance
Page Issue B
Hydraulic Oil Reservoir
Return Filter
The filter should be changed every 1000 hours, however there is an integral filter indicator on the side
of the filter head and, should this indicate red whilst the suction fan is operating, i.e. body raised, then
the filter is contaminated and requires changing at an earlier interval.
Renewing the Return Filter
Unscrew cover (
A
) and lift out the cartridge element (
B
). Fit new cartridge and screw on the cover
Renewing the Suction Filters
Note: Drain Oil Before Removing Suction Filters.
The oil can be drained by removing the drain plug (
C
) located under the systems locker or by using a
propriety vacuum pump or oil extractor/syringe.
The filters (
D
) should be changed whilst the system is empty.
System Refilling
The system capacity dry is 61 litres.
Raise the body and engage the body prop
(E)
in its highest
position. The level
(F)
should be 10mm above the lower red line
(G)
on the gauge.
It is important that the correct level is maintained as under filling
can adversely affect the heat dissipation rate of the oil, whilst over
filling can cause oil to overflow when the body is lowered.
M02MA-056
A
B
D
C
Hydraulic Oil
Reservoir Gauge
M02MA-057
10mm
max
G
F
E
Before changing the filter ensure the oil is cold.
Before removing the return filter. Ensure no pressure is present by allowing the system to
rest for a short time after turning off the equipment.
Safety Notice
VS - Twin Engine
HYDRAULICS