SECTION 3
3-1
Part No. 001-3474-002
PROGRAMMING
3.1 INTRODUCTION
The information in Section 3.2 describes synthesizer programming protocol. This information can be used as
a basis for designing the synthesizer programming hardware and software required.
3.2 DM3474 SYNTHESIZER DATA PROTOCOL
Programming of the dividers and the charge pumps are performed on a 3-line bus; SYNTH ENABLE,
SYNTH DATA, AND SYNTH CLK. On initial power up three 34-bit words are required to load the 3474 Data
Transceiver. After the initial load, one 32-bit word can be used to change channels.
The SA7025 Synthesizer IC uses four address words; D, C, B and A (see Figure 3-4). The C word is not used
in the 3474. The 24- and 32-bit words contain one or four address bits, depending on the address bits, the data is
latched into registers. When the A-word is loaded, the data of these temporary registers is loaded together with the
A-word into the work
registers.
3.2.1 D-WORD
Refer to Figure 3-1.
TCXO Reference Frequency is 17.5 MHz.
Loop Reference Frequency is 50 kHz.
Reference Divide (NR) = 17.5 MHz
÷
50 kHz =350 Decimal or 000101011110 Binary.
The 3474 has frequency resolution of 6.25 kHz and 10 kHz. When programming 6.25 kHz frequency
resolution use FMOD=8. When programming 10 kHz frequency resolution use FMOD=5.
Example:
(FCM)
÷
FMOD = 50 kHz
÷
8 = 6.25 kHz
(FCM)
÷
FMOD = 50 kHz
÷
5 = 10 kHz
Where:
FCM = Loop Reference Frequency
FMOD = Fractional N Modulus
Since FMC is the same for both 6.25 kHz and 10 kHz the loop dynamics are very similar and the same loop
filter values can be used.
Содержание DM3474
Страница 2: ......
Страница 4: ......
Страница 8: ...TABLE OF CONTENTS iv This page intentionally left blank...
Страница 20: ...PROGRAMMING 3 4 Part No 001 3474 002 Figure 3 2 B WORD Figure 3 3 A WORD...
Страница 21: ...PROGRAMMING 3 5 Part No 001 3474 002 Figure 3 4 SERIAL INPUT WORD FORMAT...
Страница 24: ...PROGRAMMING 3 8 Part No 001 3474 002 This page intentionally left blank...
Страница 42: ...SERVICING 5 6 Part No 001 3474 002 This page intentionally left blank...
Страница 48: ...ALIGNMENT PROCEDURE AND PERFORMANCE TESTS 6 6 Part No 001 3474 002 Figure 6 3 ALIGNMENT POINTS DIAGRAM R509...
Страница 60: ...SCHEMATICS AND COMPONENT LAYOUTS 8 2 Part No 001 3474 002 Figure 8 1 VCO COMPONENT LAYOUT COMPONENT SIDE VIEW...
Страница 64: ...SCHEMATICS AND COMPONENT LAYOUTS 8 6 Part No 001 3474 002 This page intentionally left blank...