©2018 Johnson Level & Tool - Rev. 1
21
3. A single press of advances to the next sequential channel.
4. The channel setting is stored in memory by simultaneously pressing
and . The red remote control LED will illuminate solidly.
To Configure the Detector Communication Channel:
1. Power on the detector.
2. Enable tracking mode by holding until the blue LED illuminates.
3. Change channels by pressing and simultaneously. Repeat
until the desired channel is reached, as indicated by “CH” and a
numeral on the LCD.
To Detect Signals in Tracking Mode:
1. Press and hold on the detector. The detector LED will illuminate
in blue, the remote signal will appear on the bottom of both the front
and back LCD displays, and the rotary laser level will begin to emit
double beeps. The laser beam will slowly sweep back and forth
within a 10° arc until it intersects the detector’s zero/on grade point
in Y-axis mode.
2. To switch tracking mode to the X-axis, press . The laser beam
will again sweep back and forth until it intersects the detector’s
zero/on grade point.
3. Once the laser beam intersects the zero/on grade point, the zero
indicator LED on the detector will illuminate in green, and the
up/down arrow at the left of the LCD display will disappear. The on-
grade indicator will appear on the front and back LCD displays, and
the laser beam will stop moving.
4. The laser beam will now be fixed on grade and will not move if the
detector’s position is changed.
2810i-Color_Manuals 5/2/18 2:16 PM Page 21