TILT Button:
When turning on the laser, the laser will self-level and begin to rotate.
The TILT symbol on the LCD will blink for thirty seconds after the laser
begins to rotate. During these thirty seconds, if the laser is moved the
laser will stop rotating, re-level and begin to rotate again. After thirty
seconds the TILT symbol will stop blinking and become solid. If the
laser is moved when the TILT symbol is solid, the laser will stop rotating.
The laser beam will blink on and off and the TILT symbol will blink
quickly alerting the user that the height of instrument may have been
changed. Pressing the level button will allow the laser to re-level and
start rotating again and the TILT mode will repeat.
Vibrate VWS Button:
When pushing this button once, the VWS symbol will be displayed on
the LCD. Note: If the TILT mode display is turned off, pushing the
VWS button will turn the TILT mode display on. In this mode, the
laser will not react to slight vibration near the laser. To turn the VWS
mode display off, push the button one more time.
MAN Button:
When holding this button in for three seconds, the laser will enter into
manual mode. The self-leveling motors are turned off and the laser
will rotate in any position. Note: Grade value cannot be entered
when in manual mode. To exit manual mode, hold the button in
again for three seconds or push the TILT button to enter TILT mode.