e. To return to the Pipe setting, tap and
simultaneously to enter the configuration mode.
f. Tap . “Pipe” will flash for five seconds on both the
main display and top-read display.
g. After five seconds, the main display reverts back to the
preconfigured engineering unit, “Pipe” will be displayed
on the sub-display and the limit is set back to ¼"/ft.
5. Roof Pitch mode, for which no limits are set. The unit will display
in units of twelfths (i.e., 1/12 = 1 inch per foot) as is customary
for roofing applications.
6. Custom mode, where you can customize the high and low limits.
See the Set Customized Limits section below for instructions.
7. 22.5° mode, for which no limits are set. The unit will alert you
when it reaches 22.5°. A custom angle may also be set within this
mode. See the Set Customized Reference Angle section below for
instructions.
8. 45.0° mode, for which no limits are set. The unit will alert you
when it reaches 45.0°. A custom angle may also be set within this
mode. See the Set Customized Reference Angle section below for
instructions.
Set Customized Limits
Once the level is in Custom mode, follow these steps to set your
customized high limit, low limit or both. If the level is inactive for five
seconds during any of these steps, the level will return to the
measuring mode.