background image

©2018 Johnson Level & Tool

23

12. Accessories

Johnson

®

accessories are available for purchase through authorized

Johnson

®

dealers. Use of non-Johnson

®

accessories will void any

applicable limited warranty and there will be NO WARRANTY. If you need
any assistance in locating any accessories, please contact our
Customer Service Department.

In the U.S., contact Johnson Level & Tool’s Customer Service
Department at 888-9-LEVELS (888-953-8357).

In Canada, contact Johnson Level & Tool’s Customer Service
Department at 800-346-6682.

2842i_Manuals  4/27/18  2:09 PM  Page 23

Содержание JLX 5700D

Страница 1: ...Series High Accuracy Digital Level Johnson Level s JLX series products are designed for professional applications and are engineered to help you work faster and more accurately We suggest you read this instruction manual thoroughly before using the instrument and save this instruction manual for future use 2842i_Manuals 4 27 18 2 08 PM Page 1 ...

Страница 2: ...ct 6 Calibrating the Product 7 Application Demonstrations 8 Troubleshooting Guide 9 Technical Specifications 10 Care and Handling 11 Product Warranty 12 Accessories 1 Kit Contents Description for Model 5700D Qty JLX Series High Accuracy Digital Level 1 Quick Start Guide 1 Instruction Manual 1 Soft Shell Carrying Case 1 2842i_Manuals 4 27 18 2 08 PM Page 2 ...

Страница 3: ...he level is in the inverted position Sub display for reference angles Removable end caps with a durable rubber finish that is wear resistant Painted top surface to minimize glare Machined bottom surface for accuracy Ergonomic rubber molded handgrip for comfort Non marring wall grip to ensure the level will not damage your surface IP65 construction that provides complete protection against dust and...

Страница 4: ...p Removable End Cap Vertical Bubble Vial Level Indicators Level Indicators Sub Display Alarm Indicators Operating Mode Indicators Battery Life Indicator Unit of Measurement Indicators Unit of Measurement Indicators inverted Measurement Reading Vertical Bubble Vial Main Display Power Backlight Calibrate Button Unit Hold Volume Button JLX Series High Accuracy Digital Level LCD Display 2842i_Manuals ...

Страница 5: ...attery cover screw in a clockwise direction to secure the cover Note Remove the batteries when storing the unit for an extended time more than three months to avoid damage to the unit should the batteries deteriorate The battery life indicator on the main LCD display will show the current battery life Battery has 100 power Battery has approximately 60 power Battery has about approximately 25 power...

Страница 6: ... the level must be moved to reach level If you invert the level both the main display and top read display will automatically flip Note If the level is tilted 30 or more the main display and top read display will read out indicating the sensor is out of its accuracy range Automatic Shut Off Manually Power Off the Level To conserve battery life this level features an automatic shut off fea ture Aft...

Страница 7: ...ements You are responsible for adherence to all federal state and local building codes Johnson Level Tool Mfg Co Inc assumes no responsibility for misapplication of this digital level by the user The bottom of the main display will show the current operating mode When powered on the level will default to the most recently used mode Press and hold to change your operating mode If the level s readin...

Страница 8: ... the American with Disabilities Act ADA The limit is 8 3 as indicated in the sub display For non standard ramp angles use Custom mode 3 ADA X mode for which the limit is that required for ramp cross angles the slope across the width by the ADA The limit is 2 0 as indicated in the sub display 4 DWV mode for which the limits are those required for setting the drain waste venting slope for either pip...

Страница 9: ...high and low limits See the Set Customized Limits section below for instructions 7 22 5 mode for which no limits are set The unit will alert you when it reaches 22 5 A custom angle may also be set within this mode See the Set Customized Reference Angle section below for instructions 8 45 0 mode for which no limits are set The unit will alert you when it reaches 45 0 A custom angle may also be set ...

Страница 10: ...et a non fractional unit of measurement degrees percent inches foot decimal inches 10 feet decimal or millimeters meter The options on the right are applicable if you have set a unit of measurement of either inches foot fraction or inches 10 feet fraction Note Once you have scrolled through the leftmost digit the values will be set and the display will revert back to the preconfigured engineering ...

Страница 11: ... Tap to select the digit to set continuing to tap will scroll through the following digit options where the bolded digit is the one to be set 88 88 88 88 88 88 88 88 3 To set the selected digit press and hold to scroll through the options of 0 through 9 4 After five seconds of inactivity the level will return to the measuring mode Turn On Off the Backlight Both the main display and the top read di...

Страница 12: ...y to configure the backlight on time 2 The LCD displays will either display 1on 5on or 10on depending on how the unit was previously configured 3 Tap to advance the on time to the next setting 4 Continue to tap until you ve reached your desired setting 5 Note Once you have entered this configuration mode three seconds of inactivity will revert the display back to normal measuring mode Adjust the V...

Страница 13: ...ently in the main display to the sub display tap The relative value will be transferred to the main display with the held value showing in the sub display 3 Tap to return to normal measuring mode Reset Factory Defaults If you wish to restore the factory default settings for the level press and hold all three buttons and for 10 seconds while power is on All customized settings will be reset to the ...

Страница 14: ...of level indicators 3 Rotate the level 180 with the top read display still facing up and the main display facing away from you 4 If the displayed valued is less than or equal to 0 05 of the value recorded in step 2 this product meets the stated accuracy and calibration is not required 5 If the displayed valued is greater than 0 05 of the value recorded in step 2 this product DOES NOT meet the stat...

Страница 15: ...e point bubble calibration method Two Point Calibration Method 7 With the level powered off position the tool on a fairly level surface such as a countertop floor or table with the top read LCD display facing up and the main display facing you 8 Press and hold CAL 1 will appear on the LCD displays 9 Tap The level will beep and CAL 2 will appear on the LCD displays 10 Rotate the level 180 with the ...

Страница 16: ...entered in the horizontal vial 2 Making sure that the position of the bubble in the horizontal vial does not change press hold and simultaneously The level will display Cal 3 Press to enter the value 4 The Cal will flash for 3 seconds emit a short beep and rdy will appear on the LCD displays indicating that the level is calibrated and ready for use 2842i_Manuals 4 27 18 2 09 PM Page 16 ...

Страница 17: ...at any desired angle Roof Pitch Measure the slope of any surface including roof pitches directly in 12ths General Carpentry While this level is generally used in slope applications its level vials make it suitable for use anywhere a standard level is used Drainage Slope Set drainage angles for proper slope to ensure adequate effluent removal from your piping systems 2842i_Manuals 4 27 18 2 09 PM P...

Страница 18: ...Replace batteries Unit will not turn off Incorrect power button operation Press and hold power button for 3 seconds to power off the level Battery indicator flashing Batteries are low Replace batteries Display reads OUT Unit tilted forward backwards in excess of allowable range Do not tilt the level beyond its allowable range Backlight not on Backlight is off Backlight timed out Turn on backlight ...

Страница 19: ...ust backlight timer Display inconsistent Unit out of calibration Calibrate unit Display not changing with movement Hold feature is engaged Press hold button to return to normal operation Numbers inverted Hold feature active Press hold button to return to normal operation Incorrect unit displayed Wrong unit selected Press unit button to change displayed unit 2842i_Manuals 4 27 18 2 09 PM Page 19 ...

Страница 20: ...positions 0 5mm m all positions Vial Sensitivity 36arcSec Drop Resistance 1M Accuracy at 70 F 21 C 05 at 0 and 90 0 10 at all other angles Accuracy over Full Temperature Range 0 15 Resolution 0 05 0 125 1 8 1 25mm 0 1 Power Supply 2 x AA alkaline batteries not included Battery Life 150 hours Display Range 4x90 Dimensions 16 24 48 or 72 L 1 1 D 2 3 W Weight 1 3 lbs 16 level 1 7 lbs 24 level 3 2 lbs...

Страница 21: ...sporting it Remove the batteries when storing the unit for an extended time more than three months to avoid damage to the unit should the batteries deteriorate Always store the unit in its case when not in use Avoid getting the unit wet Keep the unit dry and clean Remove any moisture or dirt with a soft dry cloth Do not use harsh chemicals strong detergents or cleaning solvents to clean the unit 2...

Страница 22: ...exclusions NOTE The user is responsible for the proper use and care of the product It is the user s responsibility to verify the calibration of the unit before each use For further assistance or if you experience problems with this product that are not addressed in this instruction manual please contact our Customer Service Department In the United States contact Johnson Level Tool s Customer Serv...

Страница 23: ...licable limited warranty and there will be NO WARRANTY If you need any assistance in locating any accessories please contact our Customer Service Department In the U S contact Johnson Level Tool s Customer Service Department at 888 9 LEVELS 888 953 8357 In Canada contact Johnson Level Tool s Customer Service Department at 800 346 6682 2842i_Manuals 4 27 18 2 09 PM Page 23 ...

Страница 24: ...24 2018 Johnson Level Tool 2842i_Manuals 4 27 18 2 09 PM Page 24 ...

Отзывы: