background image

JOHNSON CONTROLS

4

FORM 155.21-W2 (1209)

FIG. 1 – 

MICROBOARD (031-02430-005)

FIG. 2 – 

I/O BOARD (031-01743-002)

LD14447

LD06820

30

71 70

80 2

2

6

1

23

25

1

1 82

1

1

31

1

9

13

1 20

1

8

1

7

44

55 56

27

16

1

42

16

3

40

15

8

41

16

0

58

152

62

155

34

164

35

33

61

29

22

64

28

32

81

18

3

2

1

95

11

19

12

45

43

26

16

2

154

153

151

150

59

15

9

36

157

156

16

16

5

16

4

17

L

CR0

CR1

C

G

R4

R14

2

R58

R52

R50

R40

R38

R22

C8

R16

CR5

R56

R60

R54

R44

R42

R34

R36

R32

R26

R28

R24

R20

R18

R17

R1

R13

U1

U4

U3

R3 R15

R11

U5

R5

C1

CR2

CR3

CR8

RV7

CR7

RV6

CR6

RV3

RV2

R30

R2

Q2

R10

R4

U2

R12

R6

U6

C6 C5

C7

C2

C3

C4

K1

K2

K4

K6

K8

K16

K15

K14

K11

K9

K10

R57

R79

R51

R76

R41

R73

R69

R70

R31

R68

R25

R65

R19

RV9

RV10

C9

TB4

R61

R59

R81

R80

R53

R55

R43

R45

R77

R74

R75

R78

R37

R39

R29

R33

R35

R72

R71

R23

R27

R66

R67

R21

R64

R63

J2

HS1

Q1

Q4

Q3

Q5

HS5

U12

TB5

R82

RV8

RV5

RV4

RV1

U8

U9

U11

TB3

R62

HS2

HS4

HS3

Q6

HS6

U13

K0

K3

K5

K7

K18

K13

K12

J1

K17

TB2

TB1

Содержание York YIA Series

Страница 1: ...nnection for the following operations Remote Stop Contacts See Fig 8 Remote Start Contacts See Fig 8 Remote Local Cycling Devices See Fig 9 Multi unit sequence See Fig 10 1 The OptiView Control Center...

Страница 2: ...ndividual shall also be familiar with and comply with all applicable governmental standards and regula tions pertaining to the task in question safety symbols The following symbols are used in this do...

Страница 3: ...L OPERATION INDIVIDUAL UNIT PUMPS 9 FIG 15 MULTIPLE UNITS TWO PARALLEL OpERATION SINGLE CHILLED WATER PUMP 9 FIG 16 REMOTE Steam Hot Water Limit SETPOINT with 0 10vdc signal 10 FIG 17 REMOTE Steam Hot...

Страница 4: ...R14 2 R58 R52 R50 R40 R38 R22 C8 R16 CR5 R56 R60 R54 R44 R42 R34 R36 R32 R26 R28 R24 R20 R18 R17 R1 R13 U1 U4 U3 R3 R15 R11 U5 R5 C1 CR2 CR3 CR8 RV7 CR7 RV6 CR6 RV3 RV2 R30 R2 Q2 R10 R4 U2 R12 R6 U6...

Страница 5: ...View Control Center is in digital analog or ISN remote op erating mode allow ing for energy management system or remote start stop control Fig 8 2 All chiller safety cut out controls are in the normal...

Страница 6: ...D06824 N O CONTACTS IN CONTROL CENTER RATED 2 AMPS INDUC TION AT 250VAC 30VDC 5 AMPS RESISTIVE AT 250VAC 30VDC closure of the Energy Management System Remote Stop Contacts causes the chiller to shutdo...

Страница 7: ...l type flow switch is used the flow switch uses the cooling effect of liquid to sense flow When the flow of liquid is sensed the solid state relay output is turned on conducting current through the mi...

Страница 8: ...tat RWTwill automatically cycle either 1 or 2 unit Timer 3TR is an additional feature which prevents simultaneous starting of lead and lag unit following a power failure and eliminates nuisance starti...

Страница 9: ...p is avoided When one unit is cut out by the sequence control Fig 12 the temperature of the supply chilled water does not change MULTIPLE UNITS TWO PARALLEL OpERATION SINGLE CHILLED WATER PUMP For thi...

Страница 10: ...inputs as follows Example if the input is 3VDC the setpoint would be set to 73 as follows SETPOINT 100 3 x 9 100 27 73 Therefore a 2 second pulse 10 3 sec 20 4 sec 30 up to 11 sec which will 100 Calc...

Страница 11: ...rammed a setpoint for 44 F base into the OptiView control center and the Remote Reset Range is programmed to be 10 F then the energy management system can remotely reset the setpoint over the range of...

Страница 12: ...et Range setpoint is for 10 F and the local Leaving Chilled Liquid Temperature Setpoint is programmed for 40 F the setpoint would be set to 44 F as follows OFFSET F 5 1 10 10 4 10 10 40 10 4 F SETPOIN...

Страница 13: ...following message SAFETYSHUTDOWN MANUALRESTART and the cause of shutdown RUN CONTACTS REMOTE RUN LIGHT AND SHUTDOWN INDICATOR PLUS EMS When run contacts are required for a Remote Run Light and or Shu...

Страница 14: ...is flowing the flow switch con tact will close If the flow switch opens for 2 seconds the unit shuts down GENERATOR BACKUP TRANSFER During a prolonged power failure the unit will shutdown without goin...

Страница 15: ...and TB6 in YORK OptiView Control Center as 115VAC source is fed from terminals 1 and 2 16 Entering and Leaving Chilled and CondenserWaterTem perature Sensors are supplied by YORK as a standard item on...

Страница 16: ...861 1001 www york com P O Box 1592 York Pennsylvania USA 17405 1592 Subject to change without notice Printed in USA Copyright by Johnson Controls Inc 2009 ALL RIGHTS RESERVED Form 155 21 W2 1209 NEW...

Отзывы: