The VRF Smart Gateway does not require periodic field
maintenance.

Troubleshooting

Table 3: Launch Issues Troubleshooting Information

Resolution

Problem

Reason

Device behavior can vary based on the device and Internet browser in use. For instance,
some devices cache browser information and do not automatically redirect users to the
VRF Smart Gateway login page when the browser is launched.

Resolution

Make sure that your device is connected to the VRF Smart Gateway's Wi-Fi network.

Direct your browser to

www.myvrfsg.com

.

If the login page is taking too long to load, try using the Ethernet connection instead.

You are not directed to the VRF
Smart Gateway login page when
you launch a web browser.

Resolution

Check your web browser settings and verify that cookies are enabled.

Every time I install the SSL
certificate on my device, it asks me
to re-install it. What should I do?

When an SSL key or certificate is corrupted, the SSL page detects it and alerts you to the
corrupted key or certificate.

However, if the corruption is minor, for example, an extra space was copied while installing
the certificate or a character was missed, the UI does not detect the problem and allows
the corrupted key or certificate to be saved. The server detects the error and returns the

Error Saving SSL Settings

message. While this correctly prevents the bad key or

certificate from being used, it does not inform you as to the source of the problem.

In this case, reinstall the SSL key or certificate as described in the

VRF Smart Gateway

Network and IT Guidance Technical Bulletin (LIT-12012341)

.

When I install the SSL key or
certificate, I receive the message
Error Saving SSL Settings.

Refer to the

VRF Smart Gateway User's Guide (LIT-12012385)

for information on Ethernet settings and SSL settings.

Technical Specifications

Table 4: VRF Smart Gateway

SI-VRFCBN02-0Sx:

VRF Smart Gateway (Includes VRF Smart Gateway and 100 to 240 VAC power

supply.)

Product Code

1

12 to 15 VDC at 5.2 W maximum

Power Consumption

Operating:

0 to 50°C (32 to 122°F)

Operating Survival:

-30 to 60°C (-22 to 140°F)

Non-Operating:

-40 to 70°C (-40 to 158°F)

Ambient Temperature
Conditions

Storage:

5 to 95% RH 30°C (86°F) maximum dew point conditions

Operating:

5 to 95% RH, 30°C (86°F) maximum dew point conditions

Ambient Humidity
Conditions

Wireless Local Area Network (WLAN) Transmission Power:

CE Compliant levels

+14.5 dBm, 54 Mbps

+12.5 dBm, 65 Mbps

Transmission Power
(Typical)

-76 dBm, 10% packet error rate (PER ), 54 Mbps

-73 dBm, 10% PER, 65 Mbps

WLAN Receiver
Sensitivity (Typical)

9

VRF Smart Gateway Installation Instructions

Содержание VRF Smart Gateway

Страница 1: ...to be up to 30 m 100 ft line of sight away Power must be supplied using the provided external power supply North American Emissions Compliance United States This equipment has been tested and found to...

Страница 2: ...unit upside down which puts the labels upside down Location Considerations Observe the following guidelines when mounting a VRF Smart Gateway Mount the VRF Smart Gateway in areas free of corrosive vap...

Страница 3: ...ace to which the unit is mounted The screw holes on the VRF Smart Gateway can accommodate M3 5 and 6 screws For information on location considerations for maximizing signal strength see the Mounting s...

Страница 4: ...h you are connecting Wiring the H Link Network To wire the H Link Network of the VRF Smart Gateway Connect the two H Link cable wires to the left terminals indicated in the following figure If the VRF...

Страница 5: ...ne disconnection or isolation may be required to completely de energize equipment Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury o...

Страница 6: ...overed VRF devices A software update may be available for your device Visit VRFPro com or contact your nearest Johnson Controls representative for the latest version Refer to the VRF Smart Gateway Use...

Страница 7: ...Fi and Ethernet Settings 1 Press and hold the reset button for 6 seconds After 2 seconds the Fault LED displays Slow Flicker behavior This changes to Fast Flicker behavior after an additional 4 second...

Страница 8: ...sion On Steady Green Ethernet Off No Wi Fi signal or no devices currently connected over Wi Fi Wi Fi strength is indicated by the number of LEDs that are lit with one lit LED indicating weak wireless...

Страница 9: ...the corrupted key or certificate to be saved The server detects the error and returns the Error Saving SSL Settings message While this correctly prevents the bad key or certificate from being used it...

Страница 10: ...d Access Pre Shared Key mode Temporal Key Integrity Protocol WPA2 EAP PEAP WPA2 EAP TLS Wireless Security One H Link port 4 pin port Network and Serial Interfaces 145 4 x 85 4 x 40 1 mm 5 72 x 3 36 x...

Страница 11: ...1 ETSI EN301 489 3 Class 2 IEC 60730 1 EN 60730 1 1 Last digit x represents non US country requirements The performance specifications are nominal and conform to acceptable industry standard For appli...

Страница 12: ...Fan Dry Cool Status MI Actual System Mode SYSTEM S 25 High Medium Low Status MI Actual Supply Fan Speed SF SPD 26 50 99 C 58 210 F Value AI Zone Temperature ZN T 27 Dirty Clean Status BI Filter Statu...

Страница 13: ...e INV HRS 11 0 655 350 Hours Value AI Compressor 2 Runtime COMP HRS 12 0 255 Hz Value AI Inverter Compressor Frequency INV FREQ 13 0 65 535 Hz Value AI Total Frequency TOTAL FREQ 14 0 100 Value AI Out...

Страница 14: ...s Enum Value Thermo off 1 Pump down 2 SW on start 3 Thermo on start 4 After defrost 5 Start control 1 6 Start control 2 7 Normal 8 Oil return 9 Defrost ready 1 10 Defrost ready 2 11 Differential press...

Страница 15: ...f synchronism 21 Na4 22 Na5 23 Normal acceleration 24 Normal deceleration 25 Constant speed 26 Overload after the acceleration 27 Overload after the deceleration 28 Overload after constant speed 29 Po...

Страница 16: ...NO 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY Building Technologies Solutio...

Отзывы: