![Johnson Controls VB09 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/johnson-controls/vb09/vb09_installation-operation-and-maintenance-manual_2024200049.webp)
49
APPENDIX
FORM 145.18-IOM1
ISSUE DATE: 8/30/2018
HEATING AND COOLING DATA RECORD SHEET
JOB NAME: _____________________________________
JOB ADDRESS: _________________________________
_______________________________________________
INSTALLER: ____________________________________
SPECIAL QUOTES/OPTIONS (YES/NO): _____________
CABINET MODEL #: _____________________________
CHASSIS MODEL #: _____________________________
OPERATING MODE (HEATING/COOLING): ___________
DUCTED/FREE DISCHARGE: ______________________
LENGTH, WIDTH, HEIGHT OF DUCT(S): _____________
_______________________________________________
SUPPLY DUCT EXTERNAL STATIC PRESSURE (iwg):
_______________________________________________
CABINET SERIAL #: _____________________________
CHASSIS SERIAL #: _____________________________
LOCATION / ROOM # OF HEAT PUMP: ______________
FLASH CODES OR FAULTS FROM CONTROL BOARD:
_______________________________________________
DOES UNIT HAVE AN INTERNAL PUMP: (YES/NO): ____
SUPPLY AIRFLOW MEASUREMENT (CFM): _________
Please attach a sketch of the duct(s) run with this form when
returned to the Applied Ducted Systems PTS team.
JOB #: _________________________________________
DATE: _________________________________________
INSTALLER'S ADDRESS: _________________________
_______________________________________________
SERVICE TECHNICIAN: __________________________
UNIT INFORMATION
VERTICAL STACKED WATER SOURCE HEAT PUMP
HEATING AND COOLING DATA RECORD SHEET
INDOOR PACKAGED EQUIPMENT
Form 145.18-CL2
Air Coil
Airflow
Airflow
Coil Inlet (Dry Bulb)
Coil Outlet (Dry Bulb)
Coil Inlet (Wet Bulb)
Coil Outlet (Wet Bulb)
Air Relative Humidity (%)
°F
°F
°F
°F
°F
Expansion Valve
Coaxial
Coil
Reversing Valve
Internal Pump Voltage: L1
L2
Internal Pump Amp Draw: L1
L2
*If installed
Fan Amp Draw: L1
L2
*May only need L1 and L2 lines
L3
Fan Voltage: L1
L2
L3
Fan Motor Speed:
°F
Liquid Line
°F
Water In
psi
°F
Water Out
psi
Water Flow:
GPM
Compressor Amp Draw: L1
L2
*May only need L1 and L2 lines
L3
Compressor Voltage: L1
L2
L3
°F
psi =
SAT °F
Superheat
Sub-cooling
Suction
Discharge
Compressor
°F
psi =
SAT °F
Содержание VB09
Страница 44: ...44 FORM 145 18 IOM1 ISSUE DATE 8 30 2018 Section 3 Maintenance THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 45: ...45 FORM 145 18 IOM1 ISSUE DATE 8 30 2018 APPENDIX LD23571 Figure 29 PSC MOTOR WIRING DIAGRAM...
Страница 46: ...46 FORM 145 18 IOM1 ISSUE DATE 8 30 2018 Appendix LD23572 Figure 30 ECM WIRING DIAGRAM...
Страница 47: ...47 Appendix FORM 145 18 IOM1 ISSUE DATE 8 30 2018 LD27633 Figure 31 CONTINUOUS FAN WITH ECM WIRING DIAGRAM...
Страница 48: ...48 FORM 145 18 IOM1 ISSUE DATE 8 30 2018 Appendix LD23574 Figure 32 MOTORIZED DAMPER ECM WIRING DIAGRAM...