Installing the HSM2HOST
This section describes how to install the HSM2HOST module.
Temporary mounting requirements
Before installing the HSM2HOST, you must temporarily mount the HSM2HOST in a location that meets
the following requirements.
l
Ensure that the location is dry.
l
Ensure that the location is within the operating temperature range.
l
Ensure that the location is central to the proposed placement of all wireless devices.
l
Mount the module in a high location. Mounting the module below ground level can reduce the range
of the system.
l
Mount the module in a location that is far away from sources of interference, such as computers,
electric motors, appliances, heating, air conditioning units, and other sources of electrical noise. Large
metal objects like heating ducts and plumbing can also shield the electromagnetic waves
l
Ensure that there are no obstructions blocking the rear of the unit.
Connecting the HSM2HOST to the alarm panel
Caution:
Ensure that you disconnect all power supplies from the system before connecting the modules
to the Corbus. Power supplies can include AC, DC, and telephone lines.
To connect the HSM2HOST to the alarm panel, complete the following steps:
1.
Connect the HSM2HOST to the four-wire Corbus in the alarm panel. For more information,
see Figure 1.
2.
Turn on the system.
Figure 1:
Wiring Diagram
- 7 -