background image

TFP298

Page 6 of 6

NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; 

TEFLON is a registered trademark of DuPont

1400 Pennbrook Parkway, Lansdale, PA 19446 | Tel1-215-362-0700

© 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.

Содержание tyco EC-5 Series

Страница 1: ...ide wall position The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe lengths to the sprinklers must be cut NOTICE The Series EC 5 Sprinklers described herein must be installed and main tained in compliance with this docu ment as well as with the applicable standards of the National Fire Protec tion Association in addition to the stan dards of any other ...

Страница 2: ...ar to the back wall and parallel to the ceiling The word TOP on the deflector is to face towards the ceiling Step 2 With pipe thread sealant applied to the pipe threads hand tighten the sprinkler into the sprinkler fitting Step 3 Tighten the sprinkler into the sprinkler fitting using only the W Type 6 Sprinkler Wrench Ref Figure 3 With reference to Figures 1 the W Type 6 Sprinkler Wrench is to be ...

Страница 3: ...Sprinklers that have been exposed to corrosive products of combustion but have not operated should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush Care must be exercised to avoid damage to the sprinklers before during and after installation Sprin klers damaged by dropping striking wrench twist slippage or the like mu...

Страница 4: ...f Figures 1 and 2 4 Minimum spacing is for lateral distance between sprinklers located along a single wall Otherwise adjacent sprinklers i e sidewall sprinklers on an adjacent wall on an opposite wall or pendent sprinklers must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized 5 6 K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER TY...

Страница 5: ...oating P N specify from Table D Recessed Escutcheon Specify Style 50 Recessed Escutch eon with specify finish P N specify Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify W Type 6 Sprinkler Wrench P N 56 000 6 387 Specify W Type 7 Recessed Sprinkler Wrench P N 56 850 4 001 SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE RAL9010 1 POLYESTER 4 SIGNAL WHITE RAL9003 POLYESTER 9 CHROME PLATE...

Страница 6: ...re Protection Association TEFLON is a registered trademark of DuPont 1400 Pennbrook Parkway Lansdale PA 19446 Telephone 1 215 362 0700 2018 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice ...