background image

TFP621

Page 8 of 8

NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; 

TECHNICAL GLASS PRODUCTS and TGP are registered trademarks of Technical Glass Products; 

FIRELITE and FIRELITE PLUS are registered trademarks of Nippon Electric Glass Co., Ltd.; TEFLON is a registered trademark of DuPont

1400 Pennbrook Parkway, Lansdale, PA 19446 | Tel1-215-362-0700

© 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.

Limited 

Warranty

For warranty terms and conditions, visit 

www.tyco-fire.com.

Ordering 

Procedure

Contact your local distributor for avail-

ability. When placing an order, indicate 

the full product name and Part Number 

(P/N).

Model CWS Specific Applications 

Concealed Pendent Vertical 

Sidewall Window Sprinkler

Specify: Model CWS Specific Applica-

tion Concealed Pendent Vertical Side-

wall Window Sprinkler, SIN TY

3498

(specify) temperature rating, and P/N 

(specify):

160°F (71°C) . . . . . . . . . . . . . . . . . .50-630-0-160

212°F (100

°

C) . . . . . . . . . . . . . . . . .50-630-0-212

Note:

 Sprinkler and Cover Plates are sepa-

rately sold. See Cover Plate Assemblies 

subsection for ordering information.

Cover Plate Assemblies

Specify: Model CWS Concealed Sprin-

kler Cover Plate Assembly, (specify) 

temperature rating, (specify) finish, 

P/N (specify):

139

°

F (59

°

C)

a

Ivory (RAL1015)  . . . . . . . . . . . . . . . 56-214-0-135

Bright Chrome  . . . . . . . . . . . . . . . . 56-214-1-135

Beige (RAL1001)  . . . . . . . . . . . . . . 56-214-2-135

Pure White (RAL9010)*  . . . . . . . . . 56-214-3-135

Signal White (RAL9003)**  . . . . . . . 56-214-4-135

Grey White (RAL9002) . . . . . . . . . . 56-214-5-135

Brown (RAL8028). . . . . . . . . . . . . . 56-214-6-135

Black (RAL9005)  . . . . . . . . . . . . . . 56-214-7-135

Brushed Brass . . . . . . . . . . . . . . . . 56-214-8-135

Brushed Chrome  . . . . . . . . . . . . . . 56-214-9-135

Custom Paint . . . . . . . . . . . . . . . . . 56-214-X-135

165

°

F (74

°

C)

b

Ivory (RAL1015)  . . . . . . . . . . . . . . . 56-214-0-165

Bright Chrome  . . . . . . . . . . . . . . . . 56-214-1-165

Beige (RAL1001)  . . . . . . . . . . . . . . 56-214-2-165

Pure White (RAL9010)*  . . . . . . . . . 56-214-3-165

Signal White (RAL9003)**  . . . . . . . 56-214-4-165

Grey White (RAL9002) . . . . . . . . . . 56-214-5-165

Brown (RAL8028). . . . . . . . . . . . . . 56-214-6-165

Black (RAL9005)  . . . . . . . . . . . . . . 56-214-7-165

Brushed Brass . . . . . . . . . . . . . . . . 56-214-8-165

Brushed Chrome  . . . . . . . . . . . . . . 56-214-9-165

Custom Paint . . . . . . . . . . . . . . . . . 56-214-X-165

a.  For use with 160°F (71°C) sprinklers
b.  For use with 212°F (100°C) sprinklers
*  Eastern Hemisphere sales only
** Previously known as Bright White

Sprinkler Wrench

Specify: W-Type 

39 

Sprinkler Wrench, 

P/N 

56-000-1-950

Содержание tyco CWS

Страница 1: ...Model CWS Window Sprinkler can be used as interior protection for windows or glazing in a sprinklered building or non sprinklered building in accordance with Section 104 of the IBC Alternate Material...

Страница 2: ...ORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING LEVER SADDLE CAP DEFLECTOR 3 3 16 DIA 81 0 mm 2 1 2 DIA 63 5 mm MOUNTING SURFACE FACE OF SPRINKLER FITTING DEFLECTOR IN OPERATED POSITION DISPOSABL...

Страница 3: ...stem Protection Type Interior Wet Systems Glass Type The following types and thicknesses of glass are recognized for use with the Model CWS Window Sprinkler Non operable heat strengthened tempered sin...

Страница 4: ...ilized the linear length of the calculated window sprinklers may be reduced but in no case shall be less than 36 linear feet 1 2 x 900 If a single fire can be expected to operate Model CWS Window Spri...

Страница 5: ...listed to protect windows when intermediate horizontal mullions are present 4 0 1 22 m MAXIMUM 0 4 101 6 mm MINIMUM 8 0 2 44 m MAXIMUM MODEL CWS CONCEALED SPRINKLER 6 0 1 83 m MINIMUM MULLION Minimum...

Страница 6: ...E THROUGH USE OF 3 0 0 9 m MINIMUM PONY WALL INSTALLATION NOTE MODEL CWS SPRINKLER SHOWN ON ONE SIDE OF GLAZING FOR CLARITY FOR GLASS TYPES OTHER THAN FIRELITE PLUS CWS CERAMIC GLASS BY TGP ALL COMBUS...

Страница 7: ...nnot be engaged sufficiently to contact the ceiling the Sprinkler Fitting must be repositioned Care and Maintenance The TYCO Model CWS Specific Appli cation Window Sprinkler must be main tained and se...

Страница 8: ...temperature rating and P N specify 160 F 71 C 50 630 0 160 212 F 100 C 50 630 0 212 Note Sprinkler and Cover Plates are sepa rately sold See Cover Plate Assemblies subsection for ordering information...