Type number selection table

Pressure controls for Non-corrosive refrigerants

Family
Code

Style 5

Style
30

Range
(bar)

Diff.
(bar)

Contact
function

Max.
Bellows

Ind.
Pack.

Code***

Bulkpack

Ind.
Pack.

(Figure)

pressure

-9300

P77L

-9320

-9400

-0.5 to 7

0.5 to 3

1

22

-9301

-0.2 to 10

1 to 4.5

1

15

P77AAA

-9302

-9322

-0.3 to 2

0.4 to 1.5

1

4

-9350

P77H

-9370

-9450

3 to 30

3 to 12

2

33

-9351

P77A

-9371

-9451

3.5 to 21

2.1 to 5.5

2

30

P77BCA

-9300

-9320

-9400

-0.5 to 7

Man. res.**

1

22

P77BEA

-9350

P77HR

-9370

-9450

3 to 30

Man. res.*

3

33

*** 

Only individual package

** 

Resetable at 0.5 bar above cut-out point

Resetable at 3 bar below cut-out point

Pressure controls for Non-corrosive refrigerants,

built in accordance with DIN 32733 and approved by TÜV Germany

Family
Code

Style 5

Style 28

Range
(bar)

Diff.
(bar)

Contact
function

Max.
Bellows

Ind.
Pack.

Code***

Bulkpack

Ind. Pack.

(Figure)

pressure

Approved
according
to PED
97/23EC
Cat. IV

P77AAW

-9300

-9320

-9800

-0.5 to 7

0.5 to 3

1

20

-9350

P77W

-9370

-9850

3 to 30

3.5 to 12

2

33

Yes

P77BCB

-9300

-9320

-9800

-0.5 to 7

Man.res.**

1

20

P77BEB

-9350

P77B

-9370

-9850

3 to 30

Man. res.*

3

33

Yes

P77BES

-9350

P77S

-9370

-9850

3 to 30

Man. res.*

3

33

Yes

*** 

Only individual package

** 

Resetable at 0.5 bar above cut-out point

Resetable at 3.5 bar below cut-out point

Pressure controls for Ammonia and Non-corrosive refrigerants,

built in accordance with DIN 32733 and approved by TÜV Germany

Family
Code

Style 15

Range
(bar)

Diff.
(bar)

Contact
function

Max.
Bellows

Ind.
Pack.

Bulkpack

(Figure)

pressure

Approved
according
to PED
97/23EC
Cat.IV

P77AAW

-9700

-0.5 to 7

0.5 to 3

1

20

-9750

3 to 30

3.5 to 12

2

33

Yes

P77BCB

-9700

-0.5 to 7

Man. res.**

1

20

P77BEB

-9750

3 to 30

Man. res.*

3

33

Yes

P77BES

-9750

3 to 30

Man. res.*

3

33

Yes

** 

Resetable at 0.5 bar above cut-out point

Resetable at 3.5 bar below cut-out point

Pressure controls for Ammonia and Non-corrosive refrigerants

Family
Code

Style 15

Range
(bar)

Diff.
(bar)

Contact
function

Max.
Bellows

Ind.
Pack.

Bulkpack

(Figure)

pressure

P77AAA

-9700

-0.5 to 7

0.5 to 3

1

20

-9750

-9770

3 to 30

3.5 to 12

2

33

P77BCA

-9700

-0.5 to 7

Man. res.**

1

20

P77BEA

-9750

3 to 30

Man. res.*

3

33

** 

Resetable at 0.5 bar above cut-out point

Resetable at 3 bar below cut-out point

Note: 100 kPa = 1 bar 

 14.5 psi

Содержание P77 Series

Страница 1: ... TÜV are included in the program DIN HP models are also tested and approved according to PED 97 23EC Cat IV Description The P77 series pressure controls may be used for control functions or limit functions depending on model number All models are provided with alarm contacts All standard models have phosphor bronze bellows and brass pressure connections Models for use with ammonia are provided wit...

Страница 2: ...rder separately or directly on a surface Mounting holes 4 5 mm diam and M4 holes are provided Adjustment Adjustment of range and differential can be done by turning the hexagonal range screw and differential screw Manual reset models have a range screw only The adjustment screw can also be locked by a lock plate accessory KIT023N600 The lock plate is only included with those devices which are conf...

Страница 3: ...70 9850 3 to 30 3 5 to 12 2 33 Yes P77BCB 9300 9320 9800 0 5 to 7 Man res 1 20 P77BEB 9350 P77B 9370 9850 3 to 30 Man res 3 33 Yes P77BES 9350 P77S 9370 9850 3 to 30 Man res 3 33 Yes Only individual package Resetable at 0 5 bar above cut out point Resetable at 3 5 bar below cut out point Pressure controls for Ammonia and Non corrosive refrigerants built in accordance with DIN 32733 and approved by...

Страница 4: ...tyle 28 Braze connection 6 mm ODM Fig 7 Style 30 Braze connection 1 4 ODF Accessories optional Fig 8 Description Application Order number Fits into style 15 For 6 mm copper or steel tubing CNR003N001R pressure connectors For 8 mm copper or steel tubing CNR003N002R Fig 9 Mounting bracket Order number 271 51L Fig 10 90 cm Capillary with 2 flare nuts 1 4 SAE Order number SEC002N600 Fig 11 Locking kit...

Страница 5: ... 5 80 5 5 10 10 8 55 16 5 25 9 70 48 5 25 13 1 2 4 3 5 6 6 26 21 5 1 5 53 1 lock plate if applied 2 two mounting holes Ø 4 5 mm knock out 3 four mounting holes Ø M4 back side 4 cable inlet grommet cable range Ø 5 to Ø 13 mm 5 power element Style 5 7 16 20 UNF male shown Style 15 1 4 18 NPT female 6 reset button Fig 12 ...

Страница 6: ... 10 10 8 55 16 5 25 9 70 48 5 25 13 1 2 4 3 5 6 6 26 21 5 1 5 53 1 lock plate if applied 2 two mounting holes Ø 4 5 mm knock out 3 four mounting holes Ø M4 back side 4 cable inlet grommet cable range Ø 5 to Ø 13 mm 5 power element Style 28 Braze connection 6 mm ODM shown Style 30 Braze connection 1 4 ODF 6 reset button Fig 13 ...

Страница 7: ...P77 Issue 13 05 2003 2003 Johnson Controls Inc Catalogue Section 6 Order No PD P77 E 7 Notes ...

Страница 8: ...die cast Contact unit Large copper backed silver cadmium contacts AgCdO on conductor leaves Accessories see pag 4 Mounting bracket Compression coupling 90 cm capillary with two flare nuts Shipping weight ind pack 0 5 kg 93xx Ind overpack 36 pcs 19 kg 97xx Bulk pack 35 pcs 18 kg 94xx 98xx The performance specifications are nominal and conform to acceptable industry standards For applications at con...

Страница 9: ...hen In Situationen in denen das Versagen eines Bedienungs elements Personenschäden oder Sachverluste nach sich ziehen kann ist der Installateur dafür verantwortlich entsprechende Vorrichtungen oder Systeme einzubauen die einem Regelversagen entgegenwirken oder die als entsprechende Frühwarnsysteme dienen Montage Hinweis AnderRückseitediesesGerätbefindetsicheineDrainage Öffnung überdie Kondenswasse...

Страница 10: ...n Jos ohjaushäiriö voi johtaa henkilö tai aineellisiin vahinkoihin asentajan velvol lisuutena on huolehtia tarvittavista lisälaitteista tai järjestelmistä jotka suojaavat ihmisiä ja laitteistoa ohjaushäiriön seurauksilta tai varoittavat häiriöstä ASENNUS Huomio Tämä laite on varustettu takaosassa sijaitsevalla tyhjennysreiällä jatkuvan kosteuden poistumisen varmistamiseksi Normaaleissa olo suhteis...

Отзывы: