Note:
This PGM does not activate for alternate communicator fault.
161 - DC Trouble
This output activates when one of the following low battery conditions is detected:
• Alarm controller low or absent battery
• Module low or absent battery
• Wireless zone low battery
• Wireless keypad low battery
• Wireless siren low battery
• Wireless key low battery
The output can be configured to follow the state of the low battery trouble(s) or it can activate for a
period of time and automatically restore.
165 - Proximity Tag Used
This output activates when the selected proximity tag is presented.
Assign this output to a user by entering a user number from 0002 to 1000. To enable this attribute
for all proximity tags, enter 000 in PGM attribute [011].
[007] - [008] PGM Configuration
.
166 - Partition Prox Used
This output activates when a proximity tag is presented at a system keypad equipped with a
proximity tag reader, including global keypads. The proximity tag must be assigned to a valid user
and the PGM must be assigned to a partition that the user has permission to access.
Assign this output to a partition in section [007], PGM Partition Assignment. Use section [011],
PGM Configuration Options, to assign a schedule. When [011] is programmed as 000, the output
activates any time a valid proximity tag is presented. When [011] is programmed as 1-4, the output
activates only when the proximity tag is presented during the scheduled interval.
175 - Bell Status and Programming Access Output
This PGM activates when the siren, Installer Programming mode or DLS/SA is active. It deactivates
after bell timeout, when Installer Programming is exited or when DLS/SA programming is
disconnected.
176 - Remote Operation
This output is activated and deactivated remotely on command from DLS software.
Note:
Not for use with UL/ULC listed installations.
184 - Open After Alarm
This output activates when the system has been disarmed after an alarm. It deactivates when a
valid user code is entered or when the PGM Output timer expires.
200 - Zone Follower - PGM By Zone
This option allows the PGM to activate when the assigned zone is opened and deactivate when the
zone is restored or, if programmed, when a valid access code is entered. This PGM follows the state
of the assigned zone, regardless of the partition the zone or PGM is assigned to.
To program which zone the PGM will follow,
[011] PGM Configuration Options
99
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual