DLS/Installer Lead In/Out Group
DLS/Installer Lead In/Out Programming
DLS/Installer Disabled
[308][312] - Bit 1 Installer Lead In - Off
[308][312] - Bit 2 Installer Lead Out - Off
[308][312] - Bit 3 DLS Lead In - Off
[308][312] - Bit 4 DLS Lead Out - Off
[308][312] - Bit 5 SA Lead In - Off
[308][312] - Bit 6 SA Lead Out - Off
Digit 5 - DLS Connection Options
Option
Programming section
DLS connection/call back setting
1
[401] Option 1 OFF
Option 3 OFF
Option 4 OFF
[406] 000
Double Call Disabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On Disabled
2
[401] Option 1 ON
Option 3 OFF
Option 4 OFF
[406] 008
Double Call Enabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
3
[401] Option 1 ON
Option 3 ON
Option 4 OFF
[406] 008
Double Call Enabled
Call Back Enabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
4
[401] Option 1 ON
Option 3 OFF
Option 4 ON
[406] 008
Double Call Enabled
Call Back Disabled
User Initiated Call Up Enabled
Number of Rings to Answer On is 8
After entering a valid 5-digit template programming code, the system prompts for the following
data in the sequence listed:
1. Central Station Telephone Number
1. Program the required central station phone number. Press [#] to complete your entry.
This phone number is entered into programming section [301][001].
2. Central Station System Account Code (4 or 6-digit code)
3. Program the system account code. All digits must be entered in order to complete your
entry.
This account code is entered into programming section [310][000].
4. Partition 1 Account Code (4 digit code)
5. Program the partition 1 account code. All digits must be entered in order to complete
your entry.
This account code is entered into programming section [310][001].
6. DLS Access Code (6-digit code)
251
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference