Johnson Controls Ducted Systems
5396713-BIM-C-0319
ELECTRIC FURNACE
MODELS: EBE*/EUE*
Downflow/Upflow
INSTALLATION MANUAL
®
For Installation In:
1. Manufactured (Mobile) Homes
2. Recreational Vehicles & Park Models
3. Modular Homes & Buildings
LIST OF SECTIONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ELECTRIC FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . 4
THERMOSTAT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
OPTIONAL AIR CONDITIONING ACCESSORIES . . . . . . . . . . . . . . 8
WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LIST OF FIGURES
Furnace Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Alcove & Closet Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Upflow Closet Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Duct Connector Depth (7990 Series) . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Duct Connector Dimensions (7990 Series) . . . . . . . . . . . . . . . . . . . . . 4
Recommended Floor Cut-out (7990 Series) . . . . . . . . . . . . . . . . . . . . 4
Duct Connector Screw Attachment (7990 Series) . . . . . . . . . . . . . . . . 5
Duct Connector Tab Attachment (7990 Series) . . . . . . . . . . . . . . . . . . 5
Installation of Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Field Wiring Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Thermostat Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
EBE10*/EUE10* Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
EBE12*/EUE12* Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
EBE15*/EUE15* Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
EBE17*/EUE17* Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
EBE20*/EUE20* Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
EBE23*/EUE23* Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
LIST OF TABLES
Duct Connector for Electric Furnaces . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
EBE/EUE Series Blower Performance . . . . . . . . . . . . . . . . . . . . . . . . 6
Physical and Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION I: GENERAL
The following list includes important facts and information regarding the
EBE/EUE furnace and its packaging inclusions:
1.
Furnace is rated at 240 volts, 60 Hz, single phase.
2.
Filters are furnished with EBE model, and are the same for all EBE
models - 16 x 20 x 1 in top and 20 x 20 x 1 in the louvered door. No
filters are furnished with EUE models. External filter base and/or
filter rack is needed for field installation.
3.
Furnace size is the same for all models. See Figure 1.
4.
Four-wire thermostat operation for heating and cooling.
5.
Coil cavity built into furnace (coil shelf accessory required for EBE
model).
6.
All furnaces are equipped with an air conditioner blower and is A/C
or Heat Pump ready (coil shelf accessory required for EBE model).
7.
Holding strap furnished on top rear of furnace.
8.
The EBE furnace is designed for downflow application, and the
EUE furnace is designed for upflow application.
9.
This furnace must not be operated without the front panel
installed.
NOTICE
This furnace and its components listed on the A/C and Heat Pump
equipment sticker are listed in combination as a system by Under-
writer's Laboratories for the United States and Canada.
FIGURE 1:
Furnace Dimensions
51-5/8”
19-5/8”
OPTIONAL BOTTOM FIELD
WIRING ENTRY
A
B
C
D
E
F
H
G
J
K
L
M
N
1-7/8”
2-5/8”
3-1/2”
1”
5-1/16”
5-1/2”
1”
5-13/16”
1-3/4”
7-13/16”
8-5/8”
9-7/16”
16-1/2”
J
H
C B
A
D
E F
G
N
M
L
K
SUB-BASE, IF
USED, ADDS
7/8” MORE TO
TOTAL HEIGHT
AND 3/8” TO
WIDTH.
THERMOSTAT
WIRING
ENTRY
FIELD
WIRING
ENTRY
A0552-001
24”