TABLE 4: 

Physical and Electrical Data

1

MODEL NUMBER

2,3

EBE10A

EUE10A

3,4

EBE12A

EUE12A

5

EBE15A

EUE15A

5

EBE17A

EUE17A

5

EBE20A

EUE20A

5

EBE23A

EUE23A

D.O.E.
Output

240 VAC

60 Hz.,1 Phase

BTU

34,000

39,000

51,000

56,000

67,000

77,000

kW

10.0

11.4

15.0

16.4

19.6

22.6

OUTPUT

CAPACITY

230 VAC

60 Hz.,1 Phase

BTU

31,000

36,000

47,000

52,000

61,000

71,000

kW

9.1

10.6

13.8

15.2

17.9

20.8

220 VAC

60 Hz.,1 Phase

BTU

29,000

33,000

43,000

48,000

57,000

65,000

kW

8.5

9.7

12.6

14.1

16.7

19.1

Element Capacity

@ 240 VAC

kW

9.6

11.2

14.4

16.0

19.2

21.6

Amps

40.0

46.7

60.0

66.7

80.0

90.0

Motor Amps @ 240 V.

4.0 Maximum

Circuit Load Amps

@ 240 V.

CKT 1

43.8

50.5

5

43.8

47.1

43.8

47.1

CKT 2

NA

NA

20.0

23.3

40.0

46.7

Filter Size for EBE in top of unit only

16 x 20 x 1

Filter Size for EBE in louvered door only

20 x 20 x 1

Shipping Weights

83

84

85

86

84

86

NOTES: 

1.  Casing or Cabinet must be permanently grounded in accordance with N.E.C. or other applicable codes.
2. Does Not require a Jumper.
3. Approved for Single Branch Circuit Service Only.
4. Jumper provided for Single Branch Circuit Only.
5. Requires Jumper Bars (P/N 3500-378P).

 WARNING

For personal safety be sure to turn the electrical power OFF at the
household service box and at the furnace circuit breakers before
attempting any service or maintenance operations. Homeowners
should never perform any maintenance which requires opening
electric box door.
Furnace is equipped with a protective shield over field wiring con-
nection. When field wiring is completed, shield must be replaced to
prevent hazard of electrical shock when using furnace disconnect.
(See Figure 10.)

!

 FIGURE 10:  

Field Wiring Shield

CIRCUIT
BREAKERS

ELECTRIC
PANEL

FIELD WIRING
PROTECTIVE
SHIELD

BLOWER

A0871-001

 FIGURE 11:  

Control Box

TRANSFORMER

LIMIT
SWITCHES

GROUND
LUGS

3500-378P* JUMPER
BARS (FOR SINGLE
BRANCH CIRCUIT
SERVICE)

THERMOSTAT
WIRES

CIRCUIT
BREAKERS

SEQUENCERS

NOTE:

As Shipped, the jumper bar assembly
is set up for bottom entry. For side
entry, the top lug can be removed and
re-positioned, as shown, to provide
proper wire bending clearances.

A0345-001

0

6

F

F

O

N

O

N

O

F

F

O

0

6

Содержание EBE Series

Страница 1: ...furnace and its packaging inclusions 1 Furnace is rated at 240 volts 60 Hz single phase 2 Filters are furnished with EBE model and are the same for all EBE models 16 x 20 x 1 in top and 20 x 20 x 1 i...

Страница 2: ...8 Installing and servicing heating cooling equipment can be hazard ous due to the electrical components Only trained and qualified personnel should install repair or service heating cooling equip ment...

Страница 3: ...led below furnace The return air opening can be located in a closet front door or a side wall above the furnace casing or in a louvered door on the furnace If opening for the return air is located in...

Страница 4: ...rnace to an under the floor supply duct system The furnace may be installed on combustible flooring without a separate sub base TABLE 1 Duct Connector for Electric Furnaces FLOOR TO DUCT DIMENSIONS FI...

Страница 5: ...ough and back up under the supply duct 8 Secure the duct connector to the floor with nails flat head screws or staples The duct connector is designed for use on ducts down to 12 in width When using th...

Страница 6: ...reaker panel General wire and breaker sizes are shown in Table 2 If sheathed cable is used refer to National Electrical Code Canadian Electrical Code and local codes for additional requirements concer...

Страница 7: ...other applicable codes 2 Does Not require a Jumper 3 Approved for Single Branch Circuit Service Only 4 Jumper provided for Single Branch Circuit Only 5 Requires Jumper Bars P N 3500 378P WARNING For p...

Страница 8: ...n 19 1 2 no wider than 18 1 4 and no deeper than 20 1 2 EUE Furnace Models No extension cabinet and coil shelf are needed for the EUE upflow fur nace The coil shelf is already installed in the EUE mod...

Страница 9: ...OCK SERVICE CONNECTION COVER MUST BE INSTALLED IF FILTERS ARE USED CLEAN REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395383 UWD B 1017 LINE LOAD XFMR 3A FUSE RE...

Страница 10: ...ER MUST BE INSTALLED IF FILTERS ARE USED CLEAN REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395384 UWD B 1017 LINE LOAD XFMR 3A FUSE RED 8 RED 9 Y G W HEAT COOL...

Страница 11: ...ED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395385 UWD B 1017 60 AMP CIRCUIT 1 BREAKER 60 AMP 240 VAC 60Hz 1 PHASE CIRCUIT 2 BREAKER GND LUG SINGLE BRANCH CIRCUIT SERVICE 240 VAC 60 Hz 1 PHASE REQUIRES...

Страница 12: ...OR OTHER PROPER INSTRUMENT HAZARD OF ELECTRICAL SHOCK SERVICE CONNECTION COVER MUST BE INSTALLED IF FILTERS ARE USED CLEAN REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE W...

Страница 13: ...REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395388 UWD A 0717 LINE LOAD XFMR 3A FUSE RED 8 RED 9 Y G W HEAT COOL T STAT BLK 1 M3 M1 M2 H2 M5 M6 H4 H3 WHT BLK S...

Страница 14: ...CH CIRCUIT SERVICE GND ECM ELECTRIC FURNACE 23kW CONDENSING UNIT CONTACTOR 240 VAC 60 Hz 1 PHASE REQUIRES JUMPER BARS P N 3500 378 YEL 13 WHT 11 M4 H1 RED SHOCK HAZARD THIS FURNACE MAY BE CONNECTED TO...

Отзывы: