Service Manual
19
7
.3.2
Button Functions
Table 2-3-2
Wired Zone Controller Button Functions
No.
Description
Functions
1
Enter/Cancel
①
.
Function selection and canceling;
②
.
Press it for 5s to view the ambient temperature; press Mode button
to select viewing outdoor ambient temperature or indoor ambient
temperature.
2
▲
①
.
Running
temperature
setting
range
of
indoor
unit:
61°F~86
℉ (
16
°C
~30
℃
);
②
.
Timer setting range: 0.5~24hr;
③
.
Setting of air function level;
④
.
Setting of energy-saving temperature;
⑤
.
Setting of cleaning class.
6
▼
3
Fan
Setting of high/medium high/medium/medium low/low/auto fan speed.
4
Mode
Setting of auto/cooling/heating/fan/dry mode of indoor unit.
5
Function
Switch over among these functions of swing/air/sleep/health/
I-Demand
/
turbo/save
and cancel
/e-heater/X-fan/clean/quiet.
7
Timer
Timer setting.
8
On/Off
Turn on/off indoor unit.
4 Mode
and
2 ▲
Memory function
Press Mode and ▲ buttons at the same time for 5s under off state of the
unit to enter/cancel memory function (If memory function is s et, indoor
unit will resume original setting state after power failure and then power
recovery. If not, indoor unit is defaulted to be off after power recovery.
(Factory default for this function is "on").
2 ▲
and
6 ▼
Lock
Upon startup of the unit without malfunction or under off state of the unit,
press ▲ and ▼ buttons at the same time for 5s to enter lock state.
All
wired zone controller buttons are locked out when lock is turned on.
Repress ▲ and ▼ buttons for 5s to quit lock state.
4 Mode
and
5 Function
Programming
function
(Unit/
controller
address)
Pressing Mode and Function buttons at the same time with the unit turned
off puts the controller into Program Mode to allow confirmation/setting of
the unit/controller address. (See below for Programming information)
5 Function
and
7 Timer
Programming
Function
(General
Parameters)
Under off state of the unit, press Function and Timer buttons at the same
time for 5s to go to the
programming
menu. Press Mode button to
scroll
through parameters
and press ▲ or ▼ buttons to set the actual value.
4 Mode
and
6 ▼
Switch between
Fahrenheit and
Celsius
Under off state of the unit, press Mode and ▼ buttons at the same time for
5s to switch between Fahrenheit and
Celsius
.
5 Function
and
6 ▼
Viewing historical
malfunction
Continuously press Function and ▼ buttons for 5s to view historical
malfunction. Then press ▲ and ▼ buttons to
scroll through listed error
codes if any.
The timer displaying position displays the sequence of
malfunction and the detailed error code.
Up to five error codes may be
displayed.
1 Enter/Cancel
and
4 Mode
Setting of
main and
secondary
wired
zone
controller
Under off state of the unit, press Enter/Cancel and Mode buttons at the
same
time for 5s to set
main and secondary wired zone
controller. Press ▲ or ▼
button to adjust.
(Additional details available in the programming section.)
Содержание DHR18CSB21S
Страница 12: ...Service Manual 3 2 Nomenclature ...
Страница 47: ...Service Manual 38 Figure 2 7 13 ...
Страница 65: ...56 H6 DC fan error Service Manual ...
Страница 73: ...64 DHR48CSB21S Service Manual Service Manual ...
Страница 92: ...83 ...