Part No. 24-11443-00006, Rev. B

5

NS8000 Series

Table 1:  Display icons

Icon

Icon name

Icon description

Hide options

Up arrow

Increases current setting

No

Down arrow

Decreases current setting

Background light Sets light background color
Background dark Sets dark background color
Brightness bar

Screen brightness setting

Brightness

Screen brightness level

Cancel

Cancels a setting change

Checkmark

Confirms a setting change

CO

2

CO

2

 measurement

Fan speed

Fan speed setting

Fan auto

Automatic fan speed

Fan speed bars

Current fan speed

Relative humidity Humidity measurement
Occupancy

Occupancy indicator

Setpoint

Configurable setpoint temperature

Network

Network connection to host controller over SA bus No

No network

Sensor not connected to host controller

No

Settings              Settings menu
Settings lock

Lockout mode

Temperature

Displays current temperature

No

Setting enabled

Toggle setting is blue 

Setting disabled Toggle setting is white
Error

Title 24 error indicator

     

Page indicator

Settings screen page indicator

    

Scroll arrows

Settings screen scroll arrows

    

Timeout

Screen timeout mode

Screen dim

Screen timeout set to dim

Screen off

Screen timeout set to turn off

Graphical display overview

Yes. See 

Hiding icons on the home 

screen.

                         

Yes. See 

Activating and deactivating the 

screen lockout mode.

E1

CO2

A

A

72

466

72.0

74.5

40

CO2

°F

E1

72

466

40

CO2

72

466

40

A

A

CO2

72

Figure 1: Temperature screen

Figure 2: Fan speed screen

Figure 3: Settings screen

Содержание 24-11443-00006

Страница 1: ...es dispositifs de sécurité ou de limitation ayant une fonction d avertissement ou de protection en cas de défaillance ou de dysfonctionnement du network sensor Mounting 466 72 0 74 5 40 CO2 F 466 ppm 72 CO2 40 North American Emissions Compliance United States This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These l...

Страница 2: ...Note Locate the network sensor away from steam or water pipes warm air stacks unconditioned areas not heated or cooled or sources of electrical interference Height requirements may vary depending on the site Network sensors without CO2 sensing are shock and vibration resistant but not shock and vibration proof Be careful not to drop the unit or mount it where it could be exposed to excessive vibra...

Страница 3: ...adhere to these wiring details causes the network sensor to function incorrectly You will not be able to connect to the system using the Bluetooth Wireless Comissioning Converter BTCVT Mobile Access Portal Gateway MAP or the handheld VAV balancing tool and you will not be able to expand the system with future offerings IMPORTANT Do not connect the SA bus ground the modular phone jack GND or the sc...

Страница 4: ...Part No 24 11443 00006 Rev B 4 NS8000 Series 5 2 1 4 SA SA COM 15 VDC 15 VDC COM 15 VDC 1 2 5 6 4 3 COM SA SA 3 ...

Страница 5: ...e setpoint temperature Network Network connection to host controller over SA bus No No network Sensor not connected to host controller No Settings Settings menu Settings lock Lockout mode Temperature Displays current temperature No Setting enabled Toggle setting is blue Setting disabled Toggle setting is white Error Title 24 error indicator Page indicator Settings screen page indicator Scroll arro...

Страница 6: ... temperature relative humidity RH or CO2 show below the relevant icon Any interaction with a display screen activates temporary occupancy mode for 2 minutes See Figure 1 to 3 for individual graphical display screens Main screens overview Viewing the settings screens 1 Tap the Settings icon to access the settings screens 2 Tap the left and right arrows at the top of the screen to scroll through the...

Страница 7: ...s icon and use the scroll arrow to navigate to the second page 2 To change the temperature unit tap the Toggle icon to switch between Fahrenheit and Celsius Title 24 error indicators In the event of a Title 24 related error the graphical screen displays the Error icon in the upper left of the display screen with the corresponding error code number for all the required state of California Title 24 ...

Страница 8: ...curacy of the CO2 concentration measurement is essential modify the offset property of the NS Series CO2 Network Sensors Zone Quality ZN Q Analog Input AI The offset represents the local atmospheric pressure in hectopascals hPa Set the offset to the known local pressure or use the local altitude value listed in Table 3 The factory default value is 978 hPa As of Release 5 3 of the Controller Config...

Страница 9: ...e measurement range 32 0 F 0 C to 104 F 40 C Temperature sensor type Digital temperature sensor Humidity sensor type Thin film capacitive sensor Ambient conditions Operating 32 F to 122 F 0 C to 50 C 10 to 90 RH noncondensing 85 F 29 C maximum dew point Storage 40 F to 122 F 40 C to 50 C 5 to 95 RH noncondensing Temperature resolution 0 5 F 0 5 C Temperature accuracy NS Series Network Zone Sensor ...

Страница 10: ...ontact Johnson Controls www johnsoncontrols com contact us APAC JOHNSON CONTROLS C O CONTROLS PRODUCT MANAGEMENT NO 32 CHANGJIJANG RD NEW DISTRICT WUXI JIANGSU PROVINCE 214028 CHINA Europe JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY NA SA JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA Single point of contact The performance specifications are nominal and conform to acceptable indu...

Отзывы: