background image

3

Sales/Spares & Replacement Help Line 01604 762881

K7

K1

K6

K2

K3

K5

K4

Item

Description

K1

CH - Central H

K2

CH - Central Heating -

K3

Installer information

K4

Reset

K5

Summer/Winter mode

K6

DHW - Domestic Hot Water -

K7

DHW - Domestic Hot Water +

FIGURE 1. QUANTEC USER CONTROL PANEL

TIME 

CONTROL

(optional)

DOMESTIC HOT 

WATER

LED DISPLAY

CENTRAL 

HEATING

FUNCTION 

MODES

RESET 

BUTTON

INSTALLER 

MODE

1.  

GENERAL INFORMATION

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT: IT IS A STATUTORY REQUIREMENT THAT ALL GAS APPLIANCES BE INSTALLED BY 

COMPETENT PERSONS, (i.e. GAS SAFE REGISTERED INSTALLERS. GAS SAFE MEMBERSHIP 

ENQUIRIES - TEL: 0800 408 5500) IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND 

USE) REGULATIONS (CURRENT EDITION). FAILURE TO COMPLY WITH THESE REGULATIONS MAY 

RESULT IN PROSECUTION.

 

Part of the installation and commissioning of this appliance is related to instructions for use by the heating 
engineer to the user where specific requirements may occur.

 

The QuanTec is a wall mounted, room sealed, condensing combination boiler, featuring full sequence 
automatic spark ignition and fan assisted combustion. On the QuanTec  HR a recuperator is fitted within the 
boiler and preheats the incoming cold DHW for additional energy savings. Due to the high efficiency of the 
boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a 
plastic waste pipe at the base of the boiler. A condensate ‘plume’ will also be visible at the flue terminal. The 
QuanTec HR are combination boilers providing both central heating and instantaneous domestic hot water.

2.  

THE BOILER CONTROL PANEL

Содержание QuanTec 24C

Страница 1: ...W AT E R V E N T I L AT I O N USER S INSTRUCTIONS QUANTEC HR COMBI High Efficiency Combination Boilers These instructions are to be left with the User Publication No ZZ 1431 3 January 2015 Quantec HR2...

Страница 2: ...ase ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that yo...

Страница 3: ...T EDITION FAILURE TO COMPLY WITH THESE REGULATIONS MAY RESULT IN PROSECUTION Part of the installation and commissioning of this appliance is related to instructions for use by the heating engineer to...

Страница 4: ...boiler The display will flash showing the radiator the small flame and temperature The flame symbol increases with the demand for heat Once temperature is reached the display will go back to standby...

Страница 5: ...e end of the pipe If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII should be sought 5 RESET THE BOILER Press the reset butt...

Страница 6: ...e Contact installer E09 Valve feed back ERROR Contact installer E12 EEPROM lockout Contact installer E15 Sensor drift lockout Fill system to 1 0bar Bleed radiators Check valves are open Reset boiler C...

Страница 7: ...diator valves are open Reset boiler Contact installer F40 Water pressure too high Check to see if the gauge is over 2 8bar Bleed radiators Reset boiler Contact installer F47 Water pressure sensor not...

Страница 8: ...andstarley co uk Reception 01604 762881 Fax 01604 767408 Johnson Starley Dravo Division Industrial H V Sales 01604 707022 sales johnsonandstarley co uk www dravo co uk Anniversary 1922 2012 In the int...

Отзывы: