ERROR CODES

E01

Ignition lockout

Check other gas appliances work

Reset boiler

Contact installer

E02

False flame lockout

Contact installer

E03

Overheat lockout

Fill system to 1.0bar

Bleed radiators

Check radiator valves are open

Reset boiler

Contact installer

E05

Fan fault

Contact installer

E08

Flame circuit failure

Contact installer

E09

Valve feed back ERROR

Contact installer

E12

EEPROM lockout

Contact installer

E15

Sensor drift lockout

Fill system to 1.0bar

Bleed radiators

Check valves are open

Reset boiler

Contact installer

E16
E17
E18

Sensor stuck lockout

Fill system to 1.0bar

Bleed radiators

Check valves are open

Reset Boiler

Contact installer

E21

ADC lockout

Contact installer

E33

Return thermistor fault

Contact Installer

E34

Low power supply lockout

Contact installer or Electrician

E35

Flow thermistor fault

Contact Installer

9.  

TROUBLE SHOOTING

Содержание QuanTec 24C

Страница 1: ...W AT E R V E N T I L AT I O N USER S INSTRUCTIONS QUANTEC HR COMBI High Efficiency Combination Boilers These instructions are to be left with the User Publication No ZZ 1431 3 January 2015 Quantec HR2...

Страница 2: ...ase ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that yo...

Страница 3: ...T EDITION FAILURE TO COMPLY WITH THESE REGULATIONS MAY RESULT IN PROSECUTION Part of the installation and commissioning of this appliance is related to instructions for use by the heating engineer to...

Страница 4: ...boiler The display will flash showing the radiator the small flame and temperature The flame symbol increases with the demand for heat Once temperature is reached the display will go back to standby...

Страница 5: ...e end of the pipe If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII should be sought 5 RESET THE BOILER Press the reset butt...

Страница 6: ...e Contact installer E09 Valve feed back ERROR Contact installer E12 EEPROM lockout Contact installer E15 Sensor drift lockout Fill system to 1 0bar Bleed radiators Check valves are open Reset boiler C...

Страница 7: ...diator valves are open Reset boiler Contact installer F40 Water pressure too high Check to see if the gauge is over 2 8bar Bleed radiators Reset boiler Contact installer F47 Water pressure sensor not...

Страница 8: ...andstarley co uk Reception 01604 762881 Fax 01604 767408 Johnson Starley Dravo Division Industrial H V Sales 01604 707022 sales johnsonandstarley co uk www dravo co uk Anniversary 1922 2012 In the int...

Отзывы: