 CONTENTS

 

 1 

 

General 

information 

3

 

2  

Boiler Control Panel 

3

 

3  

To light the boiler 

4

 4. 

 

Operating 

Functions 

4

 

5  

Reset the Boiler 

5

 

6  

Servicing & Maintenance 

5

 

7  

Escape of Gas 

5

 8 

 

Cleaning 

5

 9 

 

Trouble 

Shooting 

6

NOTE

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER 

AFTER INSTALLATION

The Benchmark Scheme

The Benchmark Scheme

Johnson & Starley Ltd is a licensed member of the Benchmark Scheme 

which aims to improve the standards of installation and commissioning of domestic heating and hot water systems 

in the UK and to encourage regular servicing to optimise safety, efficiency and performance.

Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit 

www.centralheating.co.uk

Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the 

installation instructions supplied with the product and that you have signed it to say that you have received a full 

and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a 

means of complying with the appropriate Building Regulations (England and Wales).

All installations must be notified to Local Area Building Control either directly or through a Competent Persons 

Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, 

write the Notification Number on the Benchmark Checklist.

This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer 

should complete the relevant Service Record on the Benchmark Checklist after each service.

The Benchmark Checklist will be required in the event of any warranty work and as supporting documentation 

relating to home improvements in the optional documents section of the Home Improvements.

In the interest of continuous development Johnson and Starley reserve the right to change specification without prior notice. 

Johnson and Starley prides itself on it’s ability to supply spare parts quickly and efficiently.

Содержание QuanTec 24C

Страница 1: ...W AT E R V E N T I L AT I O N USER S INSTRUCTIONS QUANTEC HR COMBI High Efficiency Combination Boilers These instructions are to be left with the User Publication No ZZ 1431 3 January 2015 Quantec HR2...

Страница 2: ...ase ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that yo...

Страница 3: ...T EDITION FAILURE TO COMPLY WITH THESE REGULATIONS MAY RESULT IN PROSECUTION Part of the installation and commissioning of this appliance is related to instructions for use by the heating engineer to...

Страница 4: ...boiler The display will flash showing the radiator the small flame and temperature The flame symbol increases with the demand for heat Once temperature is reached the display will go back to standby...

Страница 5: ...e end of the pipe If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII should be sought 5 RESET THE BOILER Press the reset butt...

Страница 6: ...e Contact installer E09 Valve feed back ERROR Contact installer E12 EEPROM lockout Contact installer E15 Sensor drift lockout Fill system to 1 0bar Bleed radiators Check valves are open Reset boiler C...

Страница 7: ...diator valves are open Reset boiler Contact installer F40 Water pressure too high Check to see if the gauge is over 2 8bar Bleed radiators Reset boiler Contact installer F47 Water pressure sensor not...

Страница 8: ...andstarley co uk Reception 01604 762881 Fax 01604 767408 Johnson Starley Dravo Division Industrial H V Sales 01604 707022 sales johnsonandstarley co uk www dravo co uk Anniversary 1922 2012 In the int...