3.1
INSTALLATION REGULATIONS
•
Building Standards (Scotland) (Consolidation) Regulations
•
Building Regulation Part L
•
Gas Safety (Installation and Use) Regulations (as amended)
•
The Water Fittings Regulations or Water by-laws in Scotland
•
Building Regulation (Northern Ireland)
•
Model and Local Authority Byelaws
•
Health & Safety Document No. 635.
•
The Electricity at Work Regulations, 1989.
•
Institute of Electrical Engineers (I.E.E) Wiring Regulations
•
EU Regulation No 811/2013 and No. 812/2013 supplement Directive 2013/20/EU
This appliance has been Tested and Certified in order to meet the necessary European Directives and comply with the
latest Building Regulations, including the efficiency requirements of the SEDBUK scheme.
•
Efficiency of Hot Water Boilers Directive 92/42/EEC
• Gas Appliance Directive 2009/142/EC
•
Low Voltage Directive 2006/95/EEC
•
Electromagnetic Compatibility Directive 93/68/EEC
3.2
BUILDING STANDARDS AND REGULATIONS
Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice.
BS 5440:1
Flues (for gas appliances of rated input not exceeding 70 kW).
BS 5440:2
Ventilation (for gas appliances of rated input not exceeding 70 kW).
BS EN 12828
Heating Systems in buildings: Design for water based heating systems.
BS EN 12831
Heating Systems in buildings: Method for calculation of the design heat load.
BS EN 14336
Heating Systems in buildings: Installation and commissioning of water based heating systems.
BS 5546
Installation of gas hot water supplies for domestic purposes (2nd Family Gases)
BS 6798
Installation of gas fired hot water boilers of rated input not exceeding 70 kW.
BS 6891
Installation of Low Pressure Gas Pipework of up to 28 mm (R1) in domestic premises (2nd family gases).
IMPORTANT:
This appliance is CE certificated for safety and performance. It is important that no modifications are made to
this appliance, unless fully approved in writing by Johnson & Starley Ltd. If in doubt please ring Johnson & Starley Ltd on
Telephone 01604 762881.
4.
SAFETY & GAS INFORMATION
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE COMMENCING WITH THE INSTALLATION
4.1
GENERAL SAFETY INFORMATION
4.1.1
An LPG unit should not be installed in a room or internal space below ground level unless one side of the sides
of the building is open to the ground.
4.1.2
Only use QuanTec original spare parts on this appliance. Failure to do so will invalidate the guarantee.
4.1.3
No artificially softened water must not be used to fill the central heating system.
4.1.4
The system can be damaged by debris entering the heat exchanger and reduce efficiency. It is recommended
that the boiler is flushed, follow these guidelines as this will protect the boiler and prolong its life.
4.1.5
It is important that the system is flushed thoroughly before the appliance is left to operate (as recommended in BS
7593) in order to maintain an efficiently operating heating system. For replacement installations, the system MUST
be flushed with the old boiler in situ, in order to prevent the QuanTec becoming a trap for system debris. Once the
system has been flushed, an inhibitor (suitable for stainless steel heat exchangers) should be added. Appropriate
inhibitors are available, for example Sentinel, Fernox and Salamander. We also recommend a Magnetic & Non
Magnetic Filtration system is fitted between the last radiator and the boiler.
4.1.6