13
Sales/Spares & Replacement Help Line 01604 762881
FIGURE 7. CARTON CONTENTS
9.
INSTALLATION INSTRUCTIONS
9.1
WALL MOUNTING TEMPLATE
Use a plumb line to make sure the unit is square. Fix the template to the wall. Mark the positions of the flue
and 4 fixing points.
9.1.1
Using a 105 mm core drill make the hole through the wall. Installations that are made from within the
building only will require a 125 mm diameter hole in order to fit the flue system.
9.1.2
Using a 7mm bit, drill a minimum of 4 fixing holes for the wall plate. Insert the Rawlplugs. Remove
the template.
9.2
FIXING THE APPLIANCE
Caution:
This appliance exceeds the
recommended weight for a one-man lift as
detailed in the Manual Handling Operations,1992
Regulations.
9.2.1
It should be noted this appliance could
contain sharp edges and care MUST be
taken when handling.
9.2.2
Screw the wall bracket to the wall using
the 4 screws provided.
9.2.3
Lift the appliance onto the fixing bracket
and lower into position.
FIGURE 8. FIXING BRACKET
FILLING LOOP PACK
GAS VALVE PACK
COPPER CONNECTIONS PACK
RETURN VALVE PACK
FLOW VALVE PACK
ACCESSORIES PACK
WALL
BRACKET
DHW PACK
CARTON CONTENT
1
Quantec Combi Appliance
1
2
Group Set Components Pack
1
Gas Valve Pack
1
Filling Loop pack
1
Return Valve Pack
1
Flow Valve Pack
1
DHW Pack
1
Accessory Pack
1
Copper connection pack
1
3
Wall Mounting Plate
1
4
Wall Mounting Template
1
5
Installation & Users Instructions
1
INSTRUCTIONS
WALL
TEMPLATE
FOR
QUANTEC
COMBI & SYSTEM
BOILERS
www.johnsonandstarle
y.co.uk
sustainable solutions
under one r
oof
H E A T I N
G
H O T W
A T E R
V E
N T I L A T
I O N
INSTALLATION, COMMISSIONING
& SERVICING INSTRUCTIONS
QUANTEC HR28C
ErP
High Efficiency Boiler
with Passive Flue
Gas Heat Recover
y
Quantec HR28C
ErP
-
G.C. No. 47-416-11
These instruc
tions are to be le
ft with the User
Publication No. ZZ 1430-7
February 2016
www.johnsonandstarle
y.co.uk
sustainable solutions
under one r
oof
H E A T I N G H
O T W AT E R
V E N T I L AT I O N
USER’S INSTRUCTIONS
QUANTEC HR/P
ErP
& COMBI/SA
ErP
High Efficiency
These instructions ar
e to be left with the User
Publication No. ZZ 1431-5
February 2016
Quantec HR28C
ErP
- G.C. No. 47-416-11
Quantec HR28CP
ErP
- G.C. No. 47-416-14
Quantec 30C
ErP
- G.C. No. 47-416-12
Quantec 30C-S
A
ErP
- G.C. No. 47-416-15
Quantec 24C
ErP